O
PERATION
Converge®
▪
Operator’s Manual
▪
MN-47238
▪
Rev 1
▪
8/22
83
How to Calibrate the Temperature Probe
Before you begin
Make sure:
▪
The oven is on, but not in cooking or holding mode.
▪
You have a thermometer.
▪
You have a container filled with ice and water.
Procedure
To calibrate the probe, do the following.
Step
Action
1.
Place the probe and the thermometer in a container of ice water and allow
the temperature to settle to 32°F (0°C).
2.
Touch
the menu icon
a
. The menu screen displays.
3.
Touch
the “Settings” icon
b
. The “General Settings” screen displays.
Continued on next page
CT-TS-014846
a
CT-TS-014849
b