MN-46411 • Rev 2 • 12/19 • 1200-SK/III Marine Cook, Hold, Smoke
Troubleshooting
Code Description
Possible Cause s
E-10
Cavity air sensor shorted
Cavity air sensor reading < 5°F (-15°C). Verify sensor integrity.
E-11
Cavity air sensor open
Cavity air sensor reading > 517°F (269°C). Verify sensor integrity.
E-20
Product probe is shorted
Oven will cook in time only
Product probe reading < 5°F (-15°C). Verify sensor integrity.
E-21
Product probe is open
Oven will cook in time only
Product Probe reading > 517°F (269°C). Verify sensor integrity.
E-30
Under temperature
Unit has been more than 25°F (14°C) below set point for longer than 90 minutes.
E-31
Over temperature
Unit has been more than 60°F (33°C) above the maximum set-point for longer than 3
minutes. Holding Cabinets with this error code are more than 145°F (81°C) above the
maximum set-point.
E-32
Safety switch open
(Aux hi-limit switch)
Contact factory.
E-38
Internal software error
Contact factory.
E-39
Sensor error
Contact factory.
E-50
Temp. measurement error
Contact factory.
E-51
Temp. measurement error
Contact factory.
E-60
Real time clock error
Data set to factory default. Ensure that date and time are correct if applicable.
E-61
Real time clock error
Contact factory.
E-64
Clock is not oscillating
Contact factory.
E-70
Configuration connector error
(DIP switch)
Refer to the electrical schematic and ensure dip switches on the control match the
settings called out on the schematic. If the dip switch settings are correct, according
to the schematic, replace the control.
E-78
Voltage low
Voltage below 90 VAC on a 125 VAC unit, or below 190 VAC on a 208-240 VAC unit.
Adjust DC voltage. See "How to Adjust DC Voltage" in this manual.
E-79
Voltage high
Voltage over 135 VAC on a 125 VAC unit, or over 250 VAC on a 208-240 VAC unit.
Adjust DC voltage. See "How to Adjust DC Voltage" in this manual.
E-80
EEPROM Error
Ensure that all temperatures and times are properly set.
Contact factory if problem persists.
E-81
EEPROM Error
Contact factory.
E-82
EEPROM Error
Contact factory.
E-83
EEPROM Error
Contact factory.
E-85
EEPROM Error
All timers, if previously on, are now off. Possible bad EEPROM.
E-86
EEPROM Error
Stored HACCP memory corrupted. HACCP Address reset to 1. Possible bad EEPROM.
Contact factory if problem persists.
E-87
EEPROM Error
Stored offsets corrupted. Offsets reset to 0. Control may need a recalibration.
Possible bad EEPROM. Contact factory if problem persists.
E-88
EEPROM Error
All timer set-points are reset to 1 minute. Timers, if previously on, are now off.
Possible bad EEPROM.
E-90
Button stuck
A button has been held down for > 60 seconds. Adjust control. Error will reset when
the problem has been resolved.
E-91
Input failure
Contact factory.
E-dS
Datakey error
Datakey digital signature incompatible. Cycle power, and install compatible Datakey
if error persists.
E-dT
Datakey error
Datakey incompatible with control. Install compatible Datakey.
E-dU
Datakey unplugged
Install Datakey and cycle power to control to clear error.
dLto
Datalogger has timed out
Cycle power. Contact factory if error persists.
dLSD
Micro SD card not plugged in
Plug in SD card and cycle power. Contact factory if error persists.
NOTE:
If in doubt, always cycle the power to the control and contact factory if the problem persists.