1. DMX mode (rEC):
The Pegasus Luminaire’s dimming level is set via a DMX controller. This controller controls the luminaire
via DMX 512a. This address can be from 001 - 512. To programming a different DMX address:
1. Depress the Hundreds, Tens, and Ones, selection switches to the desired DMX address
number
(001
to
512).
2. The display goes blank* and comes back again, confirming the new DMX address, displays it
for 4 seconds, then display goes blank*.
[
Default
DMX
address
001]
NOTE: When valid DMX is present the “Ones” decimal point will remain illuminated.
2. Standalone mode:
When in Standalone mode, the Pegasus Luminaire does not require a DMX control signal.
To enter Standalone mode (or exit back to DMX (rEC) mode):
Wait a few seconds until the display goes blank*, then do the following button sequence:
1.
press and hold the [ ONES ] button,
2.
press and hold the [ TENS] button,
3.
release the [ ONES ] button,
4.
release the [ TENS ] button. When in Standalone mode the unit will ignore DMX input,
once in Standalone mode the ONES and TENS indicator will remain lit.
5.
Unit Preset level is set (0 to 100%) using [TENS] and [ONES] buttons : (00 to 99) (L00=0%),
(L99=100%
full).
6.
IMPORTANT NOTE: Unit must be in Control State (below) inorder for above output to take
effect.
A.
Control
/
Receive
State:
Note: Only one unit per DMX string should be set to Control State to avoid data conflict.
When in Standalone Mode the Pegasus can also enter into a Control State. The Luminaire will transmit its
Preset level on DMX channel 1, so that it acts like a console to control the other units that are connected
via DMX cable. If unit is in DMX mode, Control State will do nothing. NOTE: When using control state to
control additional Luminaires, the additional units on the DMX lan must be in DMX mode and set to DMX
Adr. 1.
When in Receive State (rEC), Unit only receives DMX, and if set to DMX channel 1, it will imitate the other
unit that is set to Control State, if connected.
To Toggle between Control and Receive state, do the following button sequence:
Wait a few seconds until the display goes blank,
1.
press and hold the [HUNDREDS ] button,
2.
press and hold the [ONES ] button,
3.
release the [HUNDREDS ] button,
4.
release the [ONES ] button;
Once in Con State the ONES, TENS, & HUNDREDS Indicator will remain Lit.
Display will blink and show Con (or rEC) for 4 seconds and then go to current mode display.
[Default is Receive State]
PEGASUS 6” and 8” Fresnel Installation
&
User’s
Manual
PAGE 11
LUMINAIRE CONTROLS -OPERATING MODES