LUMINAIRE CONTROLS - INFO DISPLAY SEQUENCE
PEGASUS 6” and 8” Fresnel Installation
&
User’s
Manual
Once in DMX CONTROL, the Pegasus Fresnel luminaire’s three digit control system provides set up and local
control for accessing all of the luminaires menu options and settings.
Upon Power-up, the three digit display will sequence:
1.
Firmware Version: (vXX) where XX = Verson number Displays for 2 seconds,
2.
Absence of DMX: (oFF, HLd, PrE, FuL) [ Default: oFF ] Displays for 2 seconds,
3.
Preset Level(L01 ~ L99) [ Default: L99 ] Displays for 2 seconds,
4.
Locked State (Loc, unL) [ Default: unL] Displays for 2 seconds,
5.
Control / ReceiveState (Con , rEC) [ Default: rEC)] Displays for 2 seconds,
6.
DMX Termination: (I--I or -----) I--I = Termination on 120ohm resistor active for DMX end of line
termination;
----
=
DMX
Termination
OFF
[Default:
----]
999 = Termination OFF, 998 = Termination ON
7.
Pxx
Set:
Personality
(dimming
curve)
601 = Linear, 602 = Incandescent fade 1, 603 = Incandescent fade 2
8.
DMX address: (001 ~512)– This is the DMX channel number. [ Default: 001] Displays for 4 seconds ;
NOTE: When valid DMX is present the “Ones” decimal point will remain illuminated.
When Luminaire has DMX termination ON the “Hundreds” Decimal point will blink.
To initiate Info Display sequence, do the following button sequence: Wait a few seconds until the display goes
blank,
1.
press and hold the [ TENS ] button,
2.
press and hold the [ HUNDREDS ] button,
3.
release the [ TENS ] button,
4.
release the [ HUNDREDS ] button.
Pressing any button in any mode activates display if it is blank, and shows appropriate display for the Operat-
ing mode.
HUNDREDS
TENS
ONES
PAGE 10
1
0
0