PAGE 9
PEGASUS 6” and 8” Fresnel Installation
&
User’s
Manual
LUMINAIRE WIRING DMX
DMX 512 XLR and RJ45 Connections
DMX 512 Signal
XLR Pin
RJ45 Pin
Common (Drain)
1
7
DMX 512 Minus (-)
2
2
DMX 512 Plus (+)
3
1
Note: Remaining pins on each connector are not used
Basic DMX512 installation consists of connecting multiple Pegasus Luminaires together (up to 32 Total devices
per DMX string) in “daisy-chain” fashion. A cable runs from the control console (or DMX512 control source) to the
DMX INPUT connection on the first Pegasus Luminaire. From the DMX OUTPUT of this Pegasus Luminaire an-
other cable runs to the DMX IN connector on the next Pegasus Luminaire (or DMX512 device to be controlled).
Special Note: at the end of each DMX Daisy chain, it is highly recommended that DMX TERMINATION is turn ON
on the last Pegasus Luminaire in the chain. The Display will show (I---I) when DMX TERMINATION is turned on.
The “Hundreds” decimal point will blink slowly when DMX TERMINATION is active. SEE PAGE 10 of this Manual
for
information
on
DMX
Termination
set
up.
NOTE: When valid DMX is present the “Ones” decimal point will remain illuminated.
NOTE: When DMX TERMINATION is active the “Hundreds” decimal point will blink slowly.
For more information on installing DMX512 control systems, the following publication is available for purchase
from the United States Institute for Theatre Technology (USITT), “Recommended Practice for DMX512: A Guide
for Users and Installers, 2nd edition” (ISBN: 9780955703522). USITT Contact Information: www.usitt.org
DMX NETWORK CONNECTIVITY
Connector Wiring -DMX/RDM
CONNECTING PEGASUS TO A DMX NETWORK
Power Feed from
Constant Power Circuit
Power daisy chain
to next luminaire via power-
CON thru connection.
DO NOT EXCEED Power feed
ratings.
SPECIAL NOTE:
PEGASUS must be set to DMX CONTROL (switch on the back of the luminare) to be controlled
via a DMX 512 system. Please select the Luminaire dim curve for local voltage to either 115VAC or 230VAC.
If switching between MAINS CONTROL and DMX CONTROL. Please remove power from Luminiaire and
wait
10 Seconds
before switching the luminaire to DMX CONTROL.
DMX512 (from Console or
Control device)
DMX512 (out from first lumi-
naire to second luminaire) NOTE
DMX DAISY CHAIN RULES