background image

INSTALLATION INSTRUCTIONS / INSTRUCTIONS D’INSTALLATION

AFS-500 LED Follow Spot

2

Important Information

IMPORTANT INFORMATION

Product Safety Notices

Warnings

FCC NOTICE

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  when  the  equipment  is  operated  in  a

commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in

accordance with the instruction manual, may cause harmful interference to radio communications.

When using electrical equipment, basic safety precautions should always be followed including the following:

a.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

.

b. Do not use outdoors unless the product is specified to operate in outdoor environments.
c. Do not mount near gas or electric heaters.
d. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by

unauthorized personnel.

e. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
f. Do not use this equipment for other than intended use.
g. Refer service to qualified personnel.

SAVE THIS DOCUMENT FOR FUTURE REFERENCE.

WARNING: RISK OF ELECTRICAL SHOCK! You must have access to a main circuit breaker or other power 

disconnect device before installing any wiring. Be sure that power is disconnected by removing fuses or 

turning the main circuit breaker off before installation. Installing the device with power on may expose you 

to dangerous voltages and damage the device. It is always recommended that a “lock out tag” device is 

installed on the appropriate circuit disconnect prior to beginning electrical work of any kind. A qualified 

electrician must perform this installation.

WARNING: Insulation between low-voltage supply and control conductors is provided by basic insulation.

WARNING: Refer to National Electrical Code® and local codes for cable specifications. Failure to use 

proper cable can result in damage to equipment or danger to personnel.

WARNING: This equipment is intended for installation in accordance with the National Electric Code® and 

local regulations. It is also intended for installation in indoor applications only. Before any electrical work 

is performed, disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the 

control. It is recommended that a qualified electrician perform this installation.

WARNING: This Lighting Fixture IS NOT for residential installation or use.

WARNING: The structure where fixture(s) is to be mounted must be capable of supporting the weight of 

the fixture and its accessories. This fixture is for temporary, portable mounting only.

WARNING: The light source contained in this luminaire shall only be replaced by the manufacturer or his 

service agent or a similar qualified person.

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE 

BY:

A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE 

HAZARDS INVOLVED. 

CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION PERTINENT, PAR UNE 

PERSONNE. 

CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.

CONSULTER UN ÉLECTRICIEN QUALIFIÉ POUR VOUS ASSURER QUE LES CONDUCTEURS DE LA 

DÉRIVATION SONT ADÉQUATS.

Содержание AFS-500

Страница 1: ...AFS 500 LED Follow Spot Installation User s Manual ...

Страница 2: ...product improvement New materials production methods and design refinements are introduced into existing products without notice as a routine expression of the philosophy For this reason any current Altman Lighting product may differ in some respect from its published description but will always equal or exceed the original design specifications unless otherwise noted Version as of 28 September 20...

Страница 3: ...r on may expose you to dangerous voltages and damage the device It is always recommended that a lock out tag device is installed on the appropriate circuit disconnect prior to beginning electrical work of any kind A qualified electrician must perform this installation WARNING Insulation between low voltage supply and control conductors is provided by basic insulation WARNING Refer to National Elec...

Страница 4: ...rson is authorized to assume Altman any other liability with the sale of Altman s products For complete warranty terms and conditions please refer to our web site at www altmanlighting com Warranty Service In order to request warranty service you must receive a Return Material Authorization RMA number prior to return Return shipments must be visibly marked with the RMA number the product must be r...

Страница 5: ...rain high humidity etc extreme tem perature changes hazardous conditions or restricted ventilation It is a good practice to add sand bag weights by others over each leg of the tripod to steady the fixture when moved Figure 2 AFS 500 LED Follow Spot Tripod Fixture Movement The fixture simply secures to the tripod via the tripod mounting bracket with the provided hardware Step 1 Place tripod in a su...

Страница 6: ...splay Overview on page 8 DMX Address is set using the buttons on the back panel ESC Escape Button Enter Button DN Down Button UP Button Control Panel See AFS 500 LED Follow Spot Control Panel for details WHITE RED GREEN AMBER LT AMB BLUE CTO IRIS DIMMER STROBE LAMP ON OFF Dimmer Slider for controlling intensity Lamp On Off turns on and off the LED source only Note does not affect any other operati...

Страница 7: ... 20 ampères circuit protecteur Ne surchargez pas les circuits WARNING If the external flexible cable or cord of this luminaire is damaged it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent Connecting Power Units are powered via an AC input cable from 100 to 240VAC 50 60Hz and draw approximately 490 Watts of power Table 2 outlines the wir...

Страница 8: ...ore information on installing DMX512 control systems the following publication is available for purchase from the United States Institute for Theatre Technology USITT Recommended Practice for DMX512 A Guide for Users and Installers 2nd edition ISBN 9780955703522 USITT Contact Information www usitt org DMX XLR Connectors Table 3 shows the pin outs and corresponding DMX signals for a 5 pin XLR conne...

Страница 9: ...s as AXXX Note During startup or calibration period the AFS 500 LED Follow Spot will make consecutive knocking sounds These sounds are normal during the calibration period Startup is the time frame where power is initially applied to the follow spot and each automated function is tested through all of its operating sequences Setting DMX Address To set the DMX address Step 1 Unit must be powered St...

Страница 10: ...e Corrosion resistant materials and hardware DMX512A network or local control via AFS 500 Controller 490 Watt Cool White Array 11800K See product specification sheet for details 7 13 LED arrays are rated for 50 000 hours of operation 100 to 240 VAC 50 60 Hz 4 08A at 120VAC 2 13A at 230VAC Fans on Lamp Off 0 39A 120VAC 46 8 Watts 0 to 45 degrees C 32 to 113 degrees F with humidity of 5 95 non conde...

Страница 11: ...d not cleaned off the optic then a mild soap and water solution can be used to gently wash the lens Repeat the cleaning with isopropyl alcohol to eliminate streaks and soap residue WARNING Under no circumstances should ammonia based cleaners acetone or other harsh solvents be used on or near the AFS 500 LED Follow spot Luminaire These types of cleaners or solvents can permanently damage the optics...

Страница 12: ... proper DMX address check settings See Setting DMX Address from the Home Screen for more information Unit is not set to DMX mode See DMX Menu for more information Disconnect and reconnect DMX input cable Check all DMX connections at control source and luminaire DMX data cable not wired correctly or has a broken conductor check DMX data cable for proper wiring See Connecting to the DMX512 Network o...

Страница 13: ...Altman Lighting 57 Alexander Street Yonkers New York 10701 1 914 476 7987 Main 1 914 966 9180 Fax www altmanlighting com 2019 Altman Stage Lighting Inc ...