background image

INSTALLATION INSTRUCTIONS / INSTRUCTIONS D’INSTALLATION

AFS-500 LED Follow Spot

10

Luminaire Care

CLEANING AND CARE

WARNING!  

All cleaning should be performed with power completely removed from the luminaire. Never 

remove protective covers when luminaire is powered. Wear appropriate protective eye wear and gloves 

when cleaning the fixture. All service and maintenance, other than described herein, should be performed 

by a qualified technician or Authorized Service Center. AT NO TIME SHOULD THE LED BE TOUCHED.

Special Cleaning and Care Instructions

Being a solid-state fixture, and unlike most fixtures, the 

AFS-500 LED Follow spot

 Luminaire requires 

very

 

little routine maintenance by the user.

The 

AFS-500  LED  Follow  spot  Luminaire 

requires  special  care  when  it  comes  to  cleaning  front  lens

 

assembly. Additional care needs to be taken with the plastic components because they are much easier to

 

scratch or damage than glass.
The following is a list of cleaning materials required to care for your 

AFS-500 LED Follow spot 

:

• Lint free lens tissue
• Lint or powder free gloves
• Reagent grade isopropyl alcohol*
• A mild soap solution.
If the lens is still dirty after using isopropyl alcohol, for instance if fingerprints or oil is just redistributed and

not cleaned off the optic, then a mild soap and water solution can be used to gently wash the lens. Repeat

the cleaning with isopropyl alcohol to eliminate streaks and soap residue.

WARNING!  

Under no circumstances should ammonia-based cleaners, acetone, or other harsh solvents 

be used on or near the 

AFS-500 LED Follow spot 

Luminaire. These types of cleaners or solvents can 

permanently damage the optics or housings of the fixture.

If you have any questions regarding the use or care of your 

AFS-500 LED Follow spot

 Luminaire, 

please

 

contact Altman Lighting technical support or your local Authorized Dealer.

Front Lens Cleaning

To clean 

each l

ens:

Step 1.  Turn off luminaire and allow to cool completely.

Step 2. Remove the front Plastic cowling and slide the lower panel forward to allow lens cleaning access to  

both sides of each lens.

Step 

3

.  Apply a small amount of reagent grade isopropyl alcohol to lint-free lens tissue. 

Step 

4

.  Wipe all debris, dirt, fingerprints, etc. from lens.

Step 

5

.  Using a second lint-free lens tissue, wipe off any alcohol residue.

Filter

 Cleaning

AS the AFS-500 is a fan cooled luminaire each of the fan filters will require routine cleaning to 
ensure fixture longevity and reliability.  Failure to carry out this routine maintainence will void the 
fixtures warranty. 

Using a Philips head screw driver remove the fan filter on the top of the unit.  Clean via dry low velocity 
compressed air from the underside of the filter. 

 

Содержание AFS-500

Страница 1: ...AFS 500 LED Follow Spot Installation User s Manual ...

Страница 2: ...product improvement New materials production methods and design refinements are introduced into existing products without notice as a routine expression of the philosophy For this reason any current Altman Lighting product may differ in some respect from its published description but will always equal or exceed the original design specifications unless otherwise noted Version as of 28 September 20...

Страница 3: ...r on may expose you to dangerous voltages and damage the device It is always recommended that a lock out tag device is installed on the appropriate circuit disconnect prior to beginning electrical work of any kind A qualified electrician must perform this installation WARNING Insulation between low voltage supply and control conductors is provided by basic insulation WARNING Refer to National Elec...

Страница 4: ...rson is authorized to assume Altman any other liability with the sale of Altman s products For complete warranty terms and conditions please refer to our web site at www altmanlighting com Warranty Service In order to request warranty service you must receive a Return Material Authorization RMA number prior to return Return shipments must be visibly marked with the RMA number the product must be r...

Страница 5: ...rain high humidity etc extreme tem perature changes hazardous conditions or restricted ventilation It is a good practice to add sand bag weights by others over each leg of the tripod to steady the fixture when moved Figure 2 AFS 500 LED Follow Spot Tripod Fixture Movement The fixture simply secures to the tripod via the tripod mounting bracket with the provided hardware Step 1 Place tripod in a su...

Страница 6: ...splay Overview on page 8 DMX Address is set using the buttons on the back panel ESC Escape Button Enter Button DN Down Button UP Button Control Panel See AFS 500 LED Follow Spot Control Panel for details WHITE RED GREEN AMBER LT AMB BLUE CTO IRIS DIMMER STROBE LAMP ON OFF Dimmer Slider for controlling intensity Lamp On Off turns on and off the LED source only Note does not affect any other operati...

Страница 7: ... 20 ampères circuit protecteur Ne surchargez pas les circuits WARNING If the external flexible cable or cord of this luminaire is damaged it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent Connecting Power Units are powered via an AC input cable from 100 to 240VAC 50 60Hz and draw approximately 490 Watts of power Table 2 outlines the wir...

Страница 8: ...ore information on installing DMX512 control systems the following publication is available for purchase from the United States Institute for Theatre Technology USITT Recommended Practice for DMX512 A Guide for Users and Installers 2nd edition ISBN 9780955703522 USITT Contact Information www usitt org DMX XLR Connectors Table 3 shows the pin outs and corresponding DMX signals for a 5 pin XLR conne...

Страница 9: ...s as AXXX Note During startup or calibration period the AFS 500 LED Follow Spot will make consecutive knocking sounds These sounds are normal during the calibration period Startup is the time frame where power is initially applied to the follow spot and each automated function is tested through all of its operating sequences Setting DMX Address To set the DMX address Step 1 Unit must be powered St...

Страница 10: ...e Corrosion resistant materials and hardware DMX512A network or local control via AFS 500 Controller 490 Watt Cool White Array 11800K See product specification sheet for details 7 13 LED arrays are rated for 50 000 hours of operation 100 to 240 VAC 50 60 Hz 4 08A at 120VAC 2 13A at 230VAC Fans on Lamp Off 0 39A 120VAC 46 8 Watts 0 to 45 degrees C 32 to 113 degrees F with humidity of 5 95 non conde...

Страница 11: ...d not cleaned off the optic then a mild soap and water solution can be used to gently wash the lens Repeat the cleaning with isopropyl alcohol to eliminate streaks and soap residue WARNING Under no circumstances should ammonia based cleaners acetone or other harsh solvents be used on or near the AFS 500 LED Follow spot Luminaire These types of cleaners or solvents can permanently damage the optics...

Страница 12: ... proper DMX address check settings See Setting DMX Address from the Home Screen for more information Unit is not set to DMX mode See DMX Menu for more information Disconnect and reconnect DMX input cable Check all DMX connections at control source and luminaire DMX data cable not wired correctly or has a broken conductor check DMX data cable for proper wiring See Connecting to the DMX512 Network o...

Страница 13: ...Altman Lighting 57 Alexander Street Yonkers New York 10701 1 914 476 7987 Main 1 914 966 9180 Fax www altmanlighting com 2019 Altman Stage Lighting Inc ...