background image

DISTRIBUTION AMPLIFIERS

6

6

OPERATION

7

The settings of the 

DA1912SX

 Distribution

Amplifier can be adjusted using Input Termination,
Video Level, and Sync Level switches as described
in Section 4. There are no other adjustments
necessary to operate the unit. The 

DA1912SX

 will

operate successfully as long as cables are
attached properly and other technical specifications
are followed.

ACCESSORIES

8

Model No.

Description

RACK MOUNTING BRACKETS

DA1295SX

Rack/Wall/Furniture Mount Mini-
brackets (2-"L" shaped brackets)

POWER SUPPLIES

PS5502US

9V 500mA Power Supply for US

PS5512UK

9V 500mA Power Supply for UK

PS5522AU

9V 500mA Power Supply for Australia

PS5532GR

9V 500mA Power Supply for Germany

PS5542JP

9V 500mA Power Supply for Japan

4 BNC to 4 BNC COAXIAL CABLE

CB4100MR

Bulk Cable 4 coaxes (500ft minimum)

CB4103MR

3 feet, 4 BNC to 4 BNC coaxial cable

CB4106MR

6 feet, 4 BNC to 4 BNC coaxial cable

CB4112MR

12 feet, 4 BNC to 4 BNC coaxial cable

CB4125MR

25 feet, 4 BNC to 4 BNC coaxial cable

CB4150MR

50 feet, 4 BNC to 4 BNC coaxial cable

CB4175MR

75 feet, 4 BNC to 4 BNC coaxial cable

CB41100MR

100 feet, 4 BNC to 4 BNC coaxial cable

CB41150MR

150 feet, 4 BNC to 4 BNC coaxial cable

4 BNC to 4 BNC COAX (Super High
Resolution)

CB4300MR

Bulk Cable 4 coaxes (500ft minimum)

CB4306MR

6 feet, 4 BNC to 4 BNC coaxial cable

CB4312MR

12 feet, 4 BNC to 4 BNC coaxial cable

CB4325MR

25 feet, 4 BNC to 4 BNC coaxial cable

CB4350MR

50 feet, 4 BNC to 4 BNC coaxial cable

CB4375MR

75 feet, 4 BNC to 4 BNC coaxial cable

CB43100MR

100 feet, 4 BNC to 4 BNC coaxial cable

CB43150MR

150 feet, 4 BNC to 4 BNC coaxial cable

Содержание DA1912SX

Страница 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0007 003 PRODUCT REVISION 1 DA1912SX 1 IN 2 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE ...

Страница 2: ...stallations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DA1912SX 1 in 2 out RGBS Distribution Amplifier TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNTING SAFETY GUIDELINES 2 INSTALLATION 2 CLEANING 2 FCC CE NOTICE 2 ABOUT YOU...

Страница 3: ...jects on top of the DA1912SX If the DA1912SX is to be mounted to a table or wall use only Altinex made mounting accessories such as mini mount brackets DA1295FC and cables for optimum setup To turn off the main power be sure to remove the cord from power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull power cord or...

Страница 4: ...nger runs depending on source signal resolution and cable quality The DA1912SX is supplied with a 9V 500mA External Power Adapter TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION DA1912SX GENERAL Inputs 1 Input Connector 4 BNC Female Outputs 2 Output Connectors Two 4 BNC Female Compatibility High resolution RGBS RGsB and RsGsBs Component S Video and Composite Video Table 1 DA1912SX General MECHANIC...

Страница 5: ...uns exceed 100 feet It is not recommended that this switch be set in the 1 0V position for shorter cable lengths as the increased level may reduce the life of CRT displays if they are overdriven 4 3 SYNC LEVEL SWITCH The Sync Level Switch allows the DA1912SX to output a Sync Level of either 2V p p or 4V p p This switch should normally be set in the 4V position Some older display equipment may requ...

Страница 6: ...e DA1912SX The monitors or projectors must be scan rate compatible with the source signal the DA1912SX does not affect scan rate Step 4 The Input Termination switch should normally be ON unless the input is being looped to another unit If the output cables are longer than 100 feet consider using the Video Level Switch to increase the gain on the outputs of the DA1912SX The Sync Level switch should...

Страница 7: ...S5542JP 9V 500mA Power Supply for Japan 4 BNC to 4 BNC COAXIAL CABLE CB4100MR Bulk Cable 4 coaxes 500ft minimum CB4103MR 3 feet 4 BNC to 4 BNC coaxial cable CB4106MR 6 feet 4 BNC to 4 BNC coaxial cable CB4112MR 12 feet 4 BNC to 4 BNC coaxial cable CB4125MR 25 feet 4 BNC to 4 BNC coaxial cable CB4150MR 50 feet 4 BNC to 4 BNC coaxial cable CB4175MR 75 feet 4 BNC to 4 BNC coaxial cable CB41100MR 100 ...

Страница 8: ...his switch should normally be set in the 4V position Some older display equipment may require a sync level of 2V in which case this switch may be used but this would be rare 5 Why and when should I use the Input Termination switch The Input Termination Switch is normally set to the ON position and provides 75 Ohm termination for the Red Green and Blue channels By setting this switch in the OFF pos...

Страница 9: ...ability in connection with the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way so as in its judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 2 RETURN POLICY It is very important to Altinex that you receive the products that you have ordered ...

Отзывы: