background image

DISTRIBUTION AMPLIFIERS

5

5

APPLICATION DIAGRAM

5

INSTALLING YOUR DISTRIBUTION
AMPLIFIER

6

 Step 1.

Make sure that the proper power supply is
being used with the unit. The use of an
incorrect power supply can result in
equipment damage not covered by
warranty.

Step 2.

Connect the power cord to the unit and
plug it into the power outlet. The power
indicator LED on the front panel will light.
This indicates that the unit is operational.

Step 3.

Connect the high resolution RGsB or
RGBS source to the 

DA1912SX

 using

coaxial cable with BNC connectors,
making sure that the colors match
correctly. Then connect one or two
monitors or projectors to the output(s) of
the 

DA1912SX

. The monitors or

projectors must be scan-rate compatible
with the source signal - the 

DA1912SX

does not affect scan rate.

Step 4.

The Input Termination switch should
normally be ON unless the input is being
looped to another unit. If the output cables
are longer than 100 feet, consider using
the Video Level Switch to increase the
gain on the outputs of the 

DA1912SX

.

The Sync Level switch should normally be
in the 4V position.

Step 5.

If the image is less than perfect, check all
the connections. The unit is very reliable
and seldom will be the cause of
malfunction. Poor quality cables may
often degrade the performance of the
product. Make sure that the cables used
are coaxial cables and that all pins are in
good condition.

CONGRATULATIONS! YOU ARE DONE.

If you experience any problems, please call

1-800-258-4623 or 1-714-990-2300 for

international calls.

Содержание DA1912SX

Страница 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0007 003 PRODUCT REVISION 1 DA1912SX 1 IN 2 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE ...

Страница 2: ...stallations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DA1912SX 1 in 2 out RGBS Distribution Amplifier TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNTING SAFETY GUIDELINES 2 INSTALLATION 2 CLEANING 2 FCC CE NOTICE 2 ABOUT YOU...

Страница 3: ...jects on top of the DA1912SX If the DA1912SX is to be mounted to a table or wall use only Altinex made mounting accessories such as mini mount brackets DA1295FC and cables for optimum setup To turn off the main power be sure to remove the cord from power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull power cord or...

Страница 4: ...nger runs depending on source signal resolution and cable quality The DA1912SX is supplied with a 9V 500mA External Power Adapter TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION DA1912SX GENERAL Inputs 1 Input Connector 4 BNC Female Outputs 2 Output Connectors Two 4 BNC Female Compatibility High resolution RGBS RGsB and RsGsBs Component S Video and Composite Video Table 1 DA1912SX General MECHANIC...

Страница 5: ...uns exceed 100 feet It is not recommended that this switch be set in the 1 0V position for shorter cable lengths as the increased level may reduce the life of CRT displays if they are overdriven 4 3 SYNC LEVEL SWITCH The Sync Level Switch allows the DA1912SX to output a Sync Level of either 2V p p or 4V p p This switch should normally be set in the 4V position Some older display equipment may requ...

Страница 6: ...e DA1912SX The monitors or projectors must be scan rate compatible with the source signal the DA1912SX does not affect scan rate Step 4 The Input Termination switch should normally be ON unless the input is being looped to another unit If the output cables are longer than 100 feet consider using the Video Level Switch to increase the gain on the outputs of the DA1912SX The Sync Level switch should...

Страница 7: ...S5542JP 9V 500mA Power Supply for Japan 4 BNC to 4 BNC COAXIAL CABLE CB4100MR Bulk Cable 4 coaxes 500ft minimum CB4103MR 3 feet 4 BNC to 4 BNC coaxial cable CB4106MR 6 feet 4 BNC to 4 BNC coaxial cable CB4112MR 12 feet 4 BNC to 4 BNC coaxial cable CB4125MR 25 feet 4 BNC to 4 BNC coaxial cable CB4150MR 50 feet 4 BNC to 4 BNC coaxial cable CB4175MR 75 feet 4 BNC to 4 BNC coaxial cable CB41100MR 100 ...

Страница 8: ...his switch should normally be set in the 4V position Some older display equipment may require a sync level of 2V in which case this switch may be used but this would be rare 5 Why and when should I use the Input Termination switch The Input Termination Switch is normally set to the ON position and provides 75 Ohm termination for the Red Green and Blue channels By setting this switch in the OFF pos...

Страница 9: ...ability in connection with the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way so as in its judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 2 RETURN POLICY It is very important to Altinex that you receive the products that you have ordered ...

Отзывы: