background image

DISTRIBUTION AMPLIFIERS

7

7

FREQUENTLY ASKED QUESTIONS

9

No:

Question

Answer

1

How many
feet of cable
can I use
with the

DA1912SX

when the
Video Level
switch is set
in the 1V
position?

Compensation for cable loss
is automatically made for
distances up to100 feet
when set normally, though
the 

DA1912SX

 can drive

signals through longer runs
depending on the source
signal resolution and cable
quality.

2

Can I use the

DA1912SX

power supply
to power 2
units at the
same time?

It is not recommended since
one power supply is supplied
with each unit. Please
consider the 

PS5581SM

, a

rack mount power supply.

3

Are outputs 1
& 2 of the

DA1912SX

buffered?

The 

DA1912SX

 has two

individually buffered outputs.

4

Why is the
Sync level
switch so
important?

The Sync Level Switch
allows the 

DA1912SX

 to

output a Sync Level of either
2V p-p or 4V p-p. This switch
should normally be set in the
4V position. Some older
display equipment may
require a sync level of 2V in
which case this switch may
be used, but this would be
rare.

5

Why and
when should
I use the
Input
Termination
switch?

The Input Termination
Switch is normally set to the
ON position and provides 75
Ohm termination for the
Red, Green, and Blue
channels. By setting this
switch in the OFF position
and using BNC "T"
connectors, the input may be
looped to another

DA1912SX

, to a local

monitor, or to some other
piece of equipment, if
desired.

6

Why is the
Video Level
switch
important?

The Video Level Switch can
be set to either the standard
0.7V output or to 1.0V
output. When the switch is
set in the 1.0V output
position, this provides
approximately a
35% increase in video signal
level. This can be used in
installations where cable
runs exceed 100 feet. It is
not recommended that this
switch be set in the 1.0V
position for shorter cable
lengths as the increased
level may reduce the life of
CRT displays if they are
overdriven.

Содержание DA1912SX

Страница 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0007 003 PRODUCT REVISION 1 DA1912SX 1 IN 2 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE ...

Страница 2: ...stallations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DA1912SX 1 in 2 out RGBS Distribution Amplifier TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNTING SAFETY GUIDELINES 2 INSTALLATION 2 CLEANING 2 FCC CE NOTICE 2 ABOUT YOU...

Страница 3: ...jects on top of the DA1912SX If the DA1912SX is to be mounted to a table or wall use only Altinex made mounting accessories such as mini mount brackets DA1295FC and cables for optimum setup To turn off the main power be sure to remove the cord from power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull power cord or...

Страница 4: ...nger runs depending on source signal resolution and cable quality The DA1912SX is supplied with a 9V 500mA External Power Adapter TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION DA1912SX GENERAL Inputs 1 Input Connector 4 BNC Female Outputs 2 Output Connectors Two 4 BNC Female Compatibility High resolution RGBS RGsB and RsGsBs Component S Video and Composite Video Table 1 DA1912SX General MECHANIC...

Страница 5: ...uns exceed 100 feet It is not recommended that this switch be set in the 1 0V position for shorter cable lengths as the increased level may reduce the life of CRT displays if they are overdriven 4 3 SYNC LEVEL SWITCH The Sync Level Switch allows the DA1912SX to output a Sync Level of either 2V p p or 4V p p This switch should normally be set in the 4V position Some older display equipment may requ...

Страница 6: ...e DA1912SX The monitors or projectors must be scan rate compatible with the source signal the DA1912SX does not affect scan rate Step 4 The Input Termination switch should normally be ON unless the input is being looped to another unit If the output cables are longer than 100 feet consider using the Video Level Switch to increase the gain on the outputs of the DA1912SX The Sync Level switch should...

Страница 7: ...S5542JP 9V 500mA Power Supply for Japan 4 BNC to 4 BNC COAXIAL CABLE CB4100MR Bulk Cable 4 coaxes 500ft minimum CB4103MR 3 feet 4 BNC to 4 BNC coaxial cable CB4106MR 6 feet 4 BNC to 4 BNC coaxial cable CB4112MR 12 feet 4 BNC to 4 BNC coaxial cable CB4125MR 25 feet 4 BNC to 4 BNC coaxial cable CB4150MR 50 feet 4 BNC to 4 BNC coaxial cable CB4175MR 75 feet 4 BNC to 4 BNC coaxial cable CB41100MR 100 ...

Страница 8: ...his switch should normally be set in the 4V position Some older display equipment may require a sync level of 2V in which case this switch may be used but this would be rare 5 Why and when should I use the Input Termination switch The Input Termination Switch is normally set to the ON position and provides 75 Ohm termination for the Red Green and Blue channels By setting this switch in the OFF pos...

Страница 9: ...ability in connection with the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way so as in its judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 2 RETURN POLICY It is very important to Altinex that you receive the products that you have ordered ...

Отзывы: