place. In the locked position, cleaning and or
replacement of the air valve disc can be performed.
5. To release the actuator, use the hex key wrench
and rotate in the open direction ¼ turn.
e lock is
spring loaded to release. Remove the hex key wrench
and allow the valve to close.
e air valve should be inspected and cleaned
weekly to ensure that it is sealing properly. A leaking
air valve or load door can produce a number of
undesirable consequences, including a low
smoldering re. When the air valve is open and the
unit is operating, moisture released from the fuel will
condense when contact is made with cooler
combustion air. Moisture and creosote can collect on
the gasket disk and on the end of the air valve tube
and in time produce a deposit that prevents the
gasket from sealing tightly. Clean o: any deposit on
the gasket disc with a cloth soaked in warm water
and detergent. Do not scrape with a knife or other
metal scraper as you may damage the silicone rubber
seal. Clean o: any deposit on the end of the tube by
using a pu7y knife. Any accumulation in the tube
should also be removed by using the ash rake as
described in Step 7 of Weekly Cleaning Procedure.
If the silicone rubber gasket shows evidence of
deterioration it should be replaced. When requesting
a replacement, be sure to specify the size (diameter)
of gasket you require.
To replace the gasket simply remove the center
bolt and nut as indicated in the exploded assembly in
this manual. Do not rmly tighten the nut on re-
installation as the new gasket needs some slight
wobble to seal properly over the air inlet tube.
YEARLY CLEANING
Following is the recommended procedure for
yearly cleaning:
1. Clean the heat exchanger.
✔
Remove the dra9 fan assembly.
✔
Use a wire brush or scraper to cleanout the
heat exchanger.
2. Clean the cyclone ash collector.
✔
Remove the top connecting Gange from the
cyclone.
✔
Clean the inside of the main body and funnel
of the cyclone with a wire brush.
✔
Clean the tube that connects the cyclone to
the boiler.
✔
Clean the boiler exit port where the cyclone
a7aches.
Air Valve Gasket
AIR VALVE MOTOR REPLACEMENT
Removing Old Damper Motor
1. Using the supplied Allen wrench, crank the
motor to the full open position.
2. us a 10 mm wrench to loosen the mounting
bolt.
3. Remove Motor.
Installing the New Damper Motor
1. Use the Allen wrench to crank damper motor
actuator to the 90 degree position. While holding the
actuator at 90 degrees use a screw driver to twist
locking mechanism which will hold actuator in
position.
2. Place motor onto air valve.
- 31 -
Note: Before starting this procedure make sure
that the spring return will operate in the correct
direction. To change the direction, just remove
the clip that holds the clamp in place. Pull the
clamp out flip the motor over and reinstall the
clamp making sure that the arrow is pointing at
the 0º mark. Reinstall the clip.
Содержание wood gun E100 SF
Страница 2: ......
Страница 24: ...Photo Smoke flap installed 19 ...
Страница 46: ...Steel Center Brick 8 Inch 41 ...
Страница 49: ...Appendix A Boiler Specification Diagram 44 ...
Страница 50: ... 45 ...
Страница 51: ... 46 ...
Страница 53: ...Appendix B Wiring Diagrams 48 ...
Страница 54: ... 49 ...
Страница 55: ... 50 ...
Страница 56: ... 51 ...
Страница 57: ... 52 ...
Страница 58: ... 53 ...
Страница 59: ... 54 ...
Страница 60: ... 55 ...
Страница 61: ...Appendix C Exploded Parts Drawings 56 ...
Страница 63: ... 58 ...
Страница 68: ...Appendix F Boiler Piping and Ducting Examples 63 ...
Страница 69: ...Wood Gun Air Inlet Ducting Installations 64 ...