To separate the motor housing you must remove
the four bolts from the end of the motor opposite of
the sha9.
ese bolts have a 5/16 bolt head.
Motor Frame Assembly Bolts
Once these bolts are removed, tap the mounting
end of the motor on the side with a rubber mallet, or
use a regular hammer along with a block of wood.
is will separate the bearing housing (end shield)
from the motor body.
Loosening Motor End Shield from Motor
e end shield, along with the armature, can then
be li9ed gently out of the motor frame. Be sure that
the beveled waster remains inside the motor housing.
Lifting the End Shield with Armature
Removing the two screws located beside the sha9
will allow you to separate the sha9, with the still
a7ached bearing, from the end shield.
Loosening Screws Securing Bearing to End Shield
Use a pulley puller, or our custom bearing puller
tool [01-100-80 101] to remove the bearing from the
sha9. You can use it on the motor bearing on either
end of the sha9.
e bearing on the sha9 end is the
one needing replacement in most instances. You may
by routine choose to replace the bearing on the fan
end every other time you replace the sha9 bearing.
- 39 -
Содержание wood gun E100 SF
Страница 2: ......
Страница 24: ...Photo Smoke flap installed 19 ...
Страница 46: ...Steel Center Brick 8 Inch 41 ...
Страница 49: ...Appendix A Boiler Specification Diagram 44 ...
Страница 50: ... 45 ...
Страница 51: ... 46 ...
Страница 53: ...Appendix B Wiring Diagrams 48 ...
Страница 54: ... 49 ...
Страница 55: ... 50 ...
Страница 56: ... 51 ...
Страница 57: ... 52 ...
Страница 58: ... 53 ...
Страница 59: ... 54 ...
Страница 60: ... 55 ...
Страница 61: ...Appendix C Exploded Parts Drawings 56 ...
Страница 63: ... 58 ...
Страница 68: ...Appendix F Boiler Piping and Ducting Examples 63 ...
Страница 69: ...Wood Gun Air Inlet Ducting Installations 64 ...