![Altera MAX 10 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/altera/max-10/max-10_user-manual_2910832053.webp)
LFR[4]
LFR[3]
LFR[2]
LFR[1]
LFR[0]
Setting (Decimal)
1
0
1
0
0
20
1
1
0
0
0
24
1
1
0
1
1
27
1
1
1
0
0
28
1
1
1
1
0
30
Table 4-4: Loop Filter High Frequency Capacitor Control
LFC[1]
LFC[0]
Setting (Decimal)
0
0
0
0
1
1
1
1
3
Related Information
•
Programmable Bandwidth
on page 2-19
•
Programmable Bandwidth with Advanced Parameters
on page 4-10
•
Programmable Bandwidth Parameter Settings
on page 6-2
Bypassing PLL Counter
Bypassing a PLL counter results in a multiplification (
M
counter) or a division (
N
,
C0
to
C4
counters) factor
of one.
Table 4-5: PLL Counter Settings
Description
PLL Scan Chain Bits [0..8] Settings
LSB
MSB
PLL counter
bypassed
X
X
X
X
X
X
X
X
1
(9)
PLL counter not
bypassed
X
X
X
X
X
X
X
X
0
(9)
To bypass any of the PLL counters, set the bypass bit to 1. The values on the other bits are ignored.
(9)
Bypass bit
4-14
Bypassing PLL Counter
UG-M10CLKPLL
2015.06.12
Altera Corporation
MAX 10 Clocking and PLL Implementation Guides