Faults/problems/troubleshooting
256
Faults/problems/troubleshooting
0000010040-002- GB
E53
Brake unit fault: Mains contactor
not in neutral position.
Request a service technician to perform a
repair.
E54
Operating error, incorrect riving
knife position or speed setting, e.g.
too fast for 450 mm saw blade. Dri-
ves cannot be started!
Check rotational speed and riving knife posi-
tion.
E55
Brake unit fault: Communication
problem with machine control unit -
brake unit is operating in default
mode, 450 mm saw blade / 4000
rpm.
Request a service technician to check the
function.
E56
Frequency converter phase failure/
overvoltage
Press any button on the control unit.
E57
Frequency converter excessive
speed
Restart the machine.
If this does not remedy the fault, request a
service technician.
E58
Frequency converter communica-
tion fault
Request a service technician to check the
function.
E59
Emergency running block 3500 rpm
Switch the main saw blade off and on again.
E61
Malfunction, drive positioning, cur-
rent consumption evaluation
Lubricate the axle
E81
Malfunction, shaft encoder
Evaluation faulty, A/B channel
Request a service technician to check the
function.
E91K
K contact error of the STOP button
If the fault occurs repeatedly, request a ser-
vice technician to check the function.
E92
K-n stop signal missing
Check the AC stop circuit
Request a service technician to check the
function.
E93K
K contact error of the START but-
ton
If the fault occurs repeatedly, request a ser-
vice technician to check the function.
E94
K free signal missing
Request a service technician to check the
function.
E99
Excess temperature of the control
electronics
Switch off machine and allow to cool down
before restarting. If fault occurs again, request
a service technician to check the function.
Tbl. 8-2 Fault messages
Fault message
Cause
Troubleshooting
Содержание ElmoDrive F45
Страница 8: ...Identification 8 Identification 0000010040 002 GB EC prototype testing certificate ...
Страница 9: ...Identification 9 0000010040 002 GB Identification ...
Страница 10: ...Identification 10 Identification 0000010040 002 GB GS test certificate ...
Страница 11: ...Identification 11 0000010040 002 GB Identification ...
Страница 12: ...Identification 12 Identification 0000010040 002 GB DGUV Test Certificate ...
Страница 13: ...Identification 13 0000010040 002 GB Identification ...
Страница 14: ...Identification 14 Identification 0000010040 002 GB C US Certificate ...
Страница 39: ...Definitions 39 0000010040 002 GB Definitions ...
Страница 116: ...Operating 116 Operating 0000010040 002 GB Fig 6 32 ELMO II start screen ...
Страница 117: ...Operating 117 0000010040 002 GB Operating Fig 6 33 Start screen Fig 6 34 Start screen tilting in both directions ...
Страница 123: ...Operating 123 0000010040 002 GB Operating 6 4 3 Tilt adjustment Fig 6 40 Tilt adjustment_ElmoDrive tilting to one side ...
Страница 124: ...Operating 124 Operating 0000010040 002 GB Fig 6 41 Tilt adjustment_ElmoDrive tilting to both sides ...
Страница 144: ...Operating 144 Operating 0000010040 002 GB Press the Cal button for 3 seconds Enter the new value Fig 6 62 Fig 6 63 ...
Страница 147: ...Operating 147 0000010040 002 GB Operating Fig 6 68 Switches for saw drives ...
Страница 152: ...Operating 152 Operating 0000010040 002 GB 6 4 10 Menu Fig 6 72 Main menu ...
Страница 171: ...Operating 171 0000010040 002 GB Operating Fig 6 92 Geometric shapes triangle Fig 6 93 Axis function mapped in ...
Страница 172: ...Operating 172 Operating 0000010040 002 GB Fig 6 94 Geometric shapes trapezoid Fig 6 95 Geometric shapes pentagon ...
Страница 180: ...Operating 180 Operating 0000010040 002 GB Fig 6 104 Entering saw blade thickness Fig 6 105 Input of a rotational speed ...
Страница 213: ...Operating 213 0000010040 002 GB Operating i Note For information on how to handle batteries see chapter 3 6 4 ...
Страница 247: ...Cleaning care 247 0000010040 002 GB Cleaning care i Note No relubrication of the saw shaft is necessary ...