![Altendorf ElmoDrive F45 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/altendorf/elmodrive-f45/elmodrive-f45_operating-manual_2910754023.webp)
Product description
23
0000010040-002- GB
Product description
3.4
Auxiliary power/power requirements
The permissible tolerance of the specified mainsvoltage is + 5 % and - 10 %.
Greater deviations will impair functionality.
Only connect the machine to a three-phase AC mains with phases L1, L2 and
L3, otherwise the brake module or the frequency converter may be destroyed.
Operating the machine together with phase converters, frequency converters
or transformer-capacitor combinations will destroy the brake module or the fre-
quency converter and power supply unit!
Screw-in fuse links of the type NEOZED D02 (utilisation category gL) should
preferably be used as back-up fuses.
The supply line must be dimensioned such that it cannot be overloaded and a
max. voltage drop < 3% occurs at nominal current.
The loop impedance and suitability of the overcurrent protection device must
be inspected/tested at the machine installation site.
The following devices can be used:
Manufacturer: Doepke switching devices; these switching devices can also be
purchased via Altendorf.
•
DFS4 040-4/0,30-B NK, release current 300 mA
•
DFS4 040-4/0,03-B NK, for personal protection
i
Note!
Devices for differential protection
(to be provided by the customer!)
In 230V400V systems, devices are generally used that detect leakage
currents < 300 mA. For switch-off in the event of a fault, RCDs (residual
current devices) with a rated differential current < 300 mA are normally
used, and for indication, fault current indicators (relays) or RCMs
(residual current monitors) are used.
Mains voltage independent devices for differential protection that also
detect differential currents (leakage currents) with DC components are to
be used.
If leakage current indicators or RCMs are used, ensure that additional
switch-off devices, e.g. circuit breakers, are provided.
(Extract from VDS Directive 2033)
If there are special safety requirements for persons setting up the equip-
ment, then frequency converters complying with EN 50178 must be
replaced by RCMAs with an isolator (preferably) or by type-B RCDs (uni-
versal-current-sensitive residual-current circuit breakers).
Содержание ElmoDrive F45
Страница 8: ...Identification 8 Identification 0000010040 002 GB EC prototype testing certificate ...
Страница 9: ...Identification 9 0000010040 002 GB Identification ...
Страница 10: ...Identification 10 Identification 0000010040 002 GB GS test certificate ...
Страница 11: ...Identification 11 0000010040 002 GB Identification ...
Страница 12: ...Identification 12 Identification 0000010040 002 GB DGUV Test Certificate ...
Страница 13: ...Identification 13 0000010040 002 GB Identification ...
Страница 14: ...Identification 14 Identification 0000010040 002 GB C US Certificate ...
Страница 39: ...Definitions 39 0000010040 002 GB Definitions ...
Страница 116: ...Operating 116 Operating 0000010040 002 GB Fig 6 32 ELMO II start screen ...
Страница 117: ...Operating 117 0000010040 002 GB Operating Fig 6 33 Start screen Fig 6 34 Start screen tilting in both directions ...
Страница 123: ...Operating 123 0000010040 002 GB Operating 6 4 3 Tilt adjustment Fig 6 40 Tilt adjustment_ElmoDrive tilting to one side ...
Страница 124: ...Operating 124 Operating 0000010040 002 GB Fig 6 41 Tilt adjustment_ElmoDrive tilting to both sides ...
Страница 144: ...Operating 144 Operating 0000010040 002 GB Press the Cal button for 3 seconds Enter the new value Fig 6 62 Fig 6 63 ...
Страница 147: ...Operating 147 0000010040 002 GB Operating Fig 6 68 Switches for saw drives ...
Страница 152: ...Operating 152 Operating 0000010040 002 GB 6 4 10 Menu Fig 6 72 Main menu ...
Страница 171: ...Operating 171 0000010040 002 GB Operating Fig 6 92 Geometric shapes triangle Fig 6 93 Axis function mapped in ...
Страница 172: ...Operating 172 Operating 0000010040 002 GB Fig 6 94 Geometric shapes trapezoid Fig 6 95 Geometric shapes pentagon ...
Страница 180: ...Operating 180 Operating 0000010040 002 GB Fig 6 104 Entering saw blade thickness Fig 6 105 Input of a rotational speed ...
Страница 213: ...Operating 213 0000010040 002 GB Operating i Note For information on how to handle batteries see chapter 3 6 4 ...
Страница 247: ...Cleaning care 247 0000010040 002 GB Cleaning care i Note No relubrication of the saw shaft is necessary ...