3
1
Voltage level TBTS
(Very Low Safety Voltage)
2
Removal tamper
3
Speaker
4
Backup battery
5
Direct power
6
OV power
7
Power supply with current limiting battery
8
Input + blocking siren
9
Input + blocking to place the sign M/A
10
Tamper circuit
All the connections are Very Low Safety Voltage in terms of the norm EN 60950. The SIREX
electric power must be supplied by a limited power source.
OPERATION
Interrupters of configuration
Position
Interrupter 1
Interrupter 2
Interrupter 3
Interrupter 4
Function
Ringing
(terminal SIR)
Signalling ON/OFF
(terminal I / 0)
Option
Modulation
type
Level of
ringing
Volume of the Beeps
signalling M/A
Beeps signalling
ON/OFF
ON Internal MIN
MIN
Audible and luminous
signalling
OFF External MAX
MAX
Only luminous
signalling
INPUT SIR
Configurations for input SIR
External
modulation
STRONG level
Time : 3 minutes
External
modulation
LOW level
Time : 3 minutes
Internal
modulation
STRONG level
Time : 31 minutes
Internal
modulation
LOW level
Time : 31 minutes
A positive continuous voltage of 9 to 16V on terminal « SIR » allows blocking or resetting the
SIREX. When this voltage disappears, the ringing alarm is activated during 3 minutes in external
modulation and 31 minutes in internal modulation (S3.1) while the flash is activated until the
return of the blocking voltage (for SIREX-F).
WARNING: only the external modulation is
allowed in outdoor space.
Note that during the power up, SIREX does not trigger even if the
blocking voltage is absent. First, all must be armed by applying the blocking signal for at least 1
second. The sound power level of modulation can be reduced (S3.2).