Voltage level TBTS 

(Very Low Safety Voltage)

 

Removal tamper 

Speaker 

Backup battery 

Direct power 

OV power 

Power supply with current limiting battery 

Input + blocking siren 

Input + blocking to place the sign M/A 

 

10 

Tamper circuit 

All the connections are Very Low Safety Voltage in terms of the norm EN 60950. The SIREX 
electric power must be supplied by a limited power source. 

 

OPERATION 

Interrupters of configuration 

Position 

Interrupter 1 

Interrupter 2 

 

Interrupter 3 

Interrupter 4 

Function 

Ringing

   

(terminal SIR) 

 

Signalling ON/OFF

  

(terminal I / 0) 

Option 

Modulation 

type 

Level of 

ringing 

 

Volume of the Beeps 

signalling M/A 

Beeps signalling 

ON/OFF 

ON Internal  MIN 

 

MIN 

Audible and luminous 

signalling 

OFF External  MAX 

 

MAX 

Only luminous 

signalling 

 

INPUT SIR 

Configurations for input SIR 

 

 

 

 

 

 

External  

modulation 

STRONG level 

Time : 3 minutes 

 

External 

modulation 

LOW level 

Time : 3 minutes 

 

Internal 

modulation 

STRONG level 

Time : 31 minutes 

 

Internal 

modulation 

LOW level 

Time : 31 minutes 

 

A positive continuous voltage of 9 to 16V on terminal « SIR » allows blocking or resetting the 
SIREX. When this voltage disappears, the ringing alarm is activated during 3 minutes in external 
modulation and 31 minutes in internal modulation (S3.1) while the flash is activated until the 
return of the blocking voltage (for SIREX-F). 

WARNING: only the external modulation is 

allowed in outdoor space. 

Note that during the power up, SIREX does not trigger even if the 

blocking voltage is absent. First, all must be armed by applying the blocking signal for at least 1 
second. The sound power level of modulation can be reduced (S3.2). 