background image

 

2

INTRODUCTION

 

You have just bought the outdoor siren self-powered 

SIREX 

of the range 

ALTEC

. Many thanks. 

Designed 

to last, Sirex comes in a moulded case made of cast aluminium with polyester paint to the 

test of time.

  

SIREX-F

 

includes an alarm light with LED technology ultra 

high brightness, which in addition to a high resistance to 
vibration and extreme temperatures offers a lifetime much 
superior to traditional solutions. 

 

1- 

Support for backup battery 

2- 

Opening tamper 

3- 

Interrupters of configuration 

4- 

Flash with leds!!! 

WARNING!!!

: Leds are type ultra 

high brightness. Do not face. 

5- 

Sensor for removal tamper 

6- 

Running cables 

SIREX has a double load regulation for the internal 
battery: 

- Regulation of charging current to 100 mA

, sufficient to charge the internal battery normally. 

In alarm, only the internal battery is required. This effectively protects the charger of the panel 
when several sirens are powered by it. 

- Regulation of charging to 13.8 Vdc:

 

Even if the charging voltage delivered by the panel is not 

high enough, Sirex amplifies it to provide to the battery a charging voltage of 13.8 Vdc to warranty a 
perfect load.

 

 

WIRING 

 

Before wiring the auto-protection, make sure that the circuit does not exceed 
60VDC/0,1A. 

 

The supply terminal « +12V DIR » can be used to provide the required current to 
operate the SIREX even in the absence or failure of the backup battery. However, there 
should be provided a source of high capacity and protected against over current that 
can be caused by a defective backup battery. 

 

The power of SIREX through the terminal « +12V CHR » is the recommended method 
because the backup battery has a constant load with a current limit at 100mA and a 
voltage regulator at 13.8Vdc. In alarm, only the internal battery is sought and protects 
effectively the charger of the panel. 

 

 If the equipment that drives the Sirex is not the one who provides the current, you have to 
connect the terminal 

« 0V » 

to this equipment to obtain a common reference.

 

 

The blocking or the resetting of the Sirex is driven by a positive control voltage of 9 to 16V 
continuous on the input 

« SIR ». 

 

The terminal « I / O » allows the placing of signs ON or OFF of the alarm system by a 
blocking voltage between 9 and 16VDC.  

 
 