17
Setting the Work Area Alarm
This alarm, when set properly, enables the operator to define a safe operating zone by setting only
two points. This results in an enhanced work area and defines the exclusion zone area. The exclusion
zone area can be visualized by connecting the two set points with a horizontal line and extending the
line upwards to create a vertical plane or wall. When the end of the boom passes through this plane,
the red warning lamp will illuminate and the display will show the message “EXCLUSION ZONE”.
SET POINT 1
SET POINT 2
OPERATING
ZONE
OPERATING
ZONE
OPERA
TING ZONE
OBSTACLE
EXCLUSION
ZONE
EXCLUSION
ZONE
SAFE
WORK
ING DIST
ANCE
m
WArnIng
ThE OPErATOr DEFInED WOrK ArEA ALArM IS A WArnIng DEvICE. ALL FunCTIOnS
rEMAIn OPErATIOnAL WhEn EnTErIng ThE OPErATOr DEFInED ExCLuSIOn ZOnE. SAFE
WOrKIng DISTAnCE IS ThE TIME IT WOuLD TAKE TO rEACT TO An ALArM, AnD FOr ThE
CrAnE MOTIOn TO BE hALTED BEFOrE EnTErIng ThE ExCLuSIOn ZOnE. IT IS IMPOrTAnT
TO SET POInTS ThAT EnSurE ThAT ThE BOOM, ATTAChMEnTS, hOOK LOAD, AnD rIggIng,
MAInTAIn A SAFE WOrKIng DISTAnCE FrOM ThE OBSTACLE. AvOID POSITIOnIng ThE
BOOM, ATTAChMEnT, LOAD, AnD rIggIng, In ThE ExCLuSIOn ZOnE WhEn MOvIng TO SET
POInTS 1 AnD 2. WhEn SELECTIng SET POInTS 1 AnD 2, EnSurE ThAT ThE LOAD WILL
MAInTAIn A SAFE DISTAnCE FrOM ThE OBSTACLE. IF ThE CrAnE Or OBSTACLE IS MOvED,
Or IF A DIFFErEnT SIZE LOAD IS LIFTED, ThE WOrK ArEA ALArM MuST BE rESET.
Press the
OPERATOR ALARM
key twice to access
the Working Area Alarm menu.
MAX
TEST
SET
12,900
1
31.0
77.5
5.3
1,000
FULL SPAN OUTRIGGERS
MAIN BOOM STOWED 31' JIB
Operator Alarm
Button