Setting Maximum Boom Length Alarm
Extend the boom to the desired maximum length.
Press the
OPERATOR ALARM
key to access the
operator alarm screen. Press the key adjacent to
“Max Length” to set to the current position.
If the length of the boom increases beyond the
maximum length set, the red warning light will flash
and the audible alarm will sound.
Press the key adjacent to “Max Length” again to turn
of the minimum boom angle alarm.
Setting Maximum Tip height Alarm
Raise the boom to the desired maximum height. Press the
OPERATOR ALARM
key to access the
operator alarm screen. Press the key adjacent to “Max Height” to set to the current position.
If the tip of the boom goes beyond the maximum height set, the red warning light will flash and the
audible alarm will sound.
Press the key adjacent to “Max Height” again to turn of the minimum boom angle alarm.
Accessing Swing and Work Area Alarms
To access the swing and work area alarms from the
main working screen, press the
OPERATOR ALARM
key twice. The information window will show the
current status of the swing and work area alarms.
Each of the four operator alarms are controlled by
keys adjacent to the text in the information window.
Each key operates as a toggle switch. If the alarm to
be set is off, pressing the corresponding key will turn
the alarm on. If the alarm to be set is on pressing the
corresponding key will turn the alarm off. When operator alarms are set, the light above the key will
be illuminated. Return to the main screen by pressing the
OPERATOR ALARM
key.