![AlpicAir ACCMI-26HRDC1A Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/alpicair/accmi-26hrdc1a/accmi-26hrdc1a_owners-manual_2906596032.webp)
27
5.6 Electrical Wiring
5.6.1 Wiring Precautions
ķ
WARNING!
Before obtaining access to terminals, all supply circuits must be disconnected.
ĸ
Ĺ
The rated voltage of the unit is as shown as Table 4
342~457V range (for three-phrase unit).
ĺ
Before turning on, verify that the voltage is within the 198~264V range(for single phrase unit) or
conditioner.
ļ
The special branch circuit breaker is installed in the permanent wiring. Always use a circuit that can
Ľ
Ļ
trip all the poles of the wiring and has an isolation distance of at least 3mm between the contacts of
each pole.
and positively.
Perform wiring work in accordance with standards so that the air conditioner can be operated safely
and electric company standards.
DC Inverter Free match Series Cassette Type Unit
Always use a special branch circuit and install a special receptacle to supply power to the air
Install a leakage special branch circuit breaker in accordance with the related laws and regulations
(3) After installing the front panel, make sure there’s no gap between the unit
WARNING!
Match the slots according to their different size.
and the front panel.
(4) Circuit of the decorative front panel.
(5) Connect the front panel to the main body through the corresponding slots.
After installing the panel, the insulated protective cover with the thickness of 1mm
shall be used to wrap the wiring terminal, Tighten the insulated glue cover on both
sides with bonding tie to fix it.