4.2 Operation
Parameter Value
Note
Default
31
a
Service calling is in st atus ON / OFF
a
0
a
–
0
service calling OFF
–
1
service calling ON after time set in parameter
56
–
2
service calling ON after time set in parameter
56
and moreover is
activated during first telephone line connection
service calling is activated after time set in parameter
56
and is repeated after
time period set in parameter
36
Parameter Value
Note
Default
32
h
For service calling are used also emergency
numbers
0
h
–
0
emergency numbers are not used. It is calling only number programm
in parameter 21
–
1
emergency numbers are used. It is calling numbers programmed in
parameter 21 and 1
List of corresponding parametres:
1 21 31 56 36
Parameter Value
Note
Default
33
i
For failure calling are used also emergency
numbers
0
i
–
0
emergency numbers are not used. It is calling only number programm
in parameter 22
–
1
emergency numbers are used. It is calling numbers programmed in
parameter 22 and 1
List of corresponding parametres:
1 22 34 38
Parameter Value
Note
Default
34
z
Activation of failure calling on input INPUT
0
z
–
0
failure calling is activated
by voltage connection
5-24V
–
1
failure calling is activated
by voltage disconnection
5-24V
List of corresponding parametres:
1 21 33 38
Parameter Value
Note
Default
35
b
Button blocking - input BLOCK
0
b
–
0
emergency call is blocking
by voltage connection
5-24V
–
1
emergency call is blocking
by voltage disconnection
5-24V