Note  1

if  you  wish  to  keep  the  connection  (extend  the  34  seconds  period)  than  the 

customer  will  think  over  the  other  setting,  so  pressing  e.g..  6,  7,  0, 

or #  form  time  to 

time  will  be  sufficient  and  the  guard  immediately  responds  by  error  tone,  but  he  will 
extend the period to hanging up.. 

3.2  PC programming

– programm Lift SET 

For  setting  of  NLLW  by  PC  you  need  special  cabel  KAB  (  RS  232  port)  and 
Programm  Lift  SET.  The  NLLW  must  be  connected  to  telephone  line 

– 

powering.  
Procedure: 

Connect the NLLW to the line 

Connect  the  NLLW  with  PC  by  KAB  cable  (if  PC  serial  port  absent,  the 
USB-COM  reduction  is  to  be  used).  The  NLLW  will  answer  and  LED  light 
on the front panel will light. 

Run the Lift SET program 

– the NLLW will report the his conversion to PC 

programming  mode  (viz.table  1  page14).    After  Liftset  program  being  run 
the  NLLW  is  in  this  mode 

–  this  status  is  indicated  by  LED  light  on  front 

panel  by  1  second  flashing.  By  loss  of  connection  it  is  necessary  to 
disconnect the cable from NLLW connect it again 

– the NLLW will answer 

and  if  Liftset  program  runs  he  will  report  his  conversion  to  programming 
mode. 

Содержание New Link Lift Watch 50

Страница 1: ...ALPHATECH TECHNOLOGIES s r o Jeremenkova 88 Praha 4 Czech Republic www alphatechtechnologies cz New Link Lift Watch Lift communicator User guide...

Страница 2: ...er PC via configuration software For connection the NLLW to PC you have to use special cabel After button pressing the NLLW enables to make phone call up 6 numbers max 16 digits in tone or pulse dial...

Страница 3: ...2 CALLING FROM LLW 19 2 2 1 Emergency call button activation 19 2 2 2 Calling from INPUT Failure call 19 2 2 3 Calling from INPUT Technical call 20 2 2 4 Service calling from timer 20 2 2 5 End of cal...

Страница 4: ...2 24V second mode is using only if you haven t power supply then you use power for current loop from telephone line CAUTION It is not galvanically isolated Third mode is external power for example but...

Страница 5: ...room call it is calling between lift cabin and machine room Incoming call it is calling coming from outside into NLLW unit The NLLW pick up you can programm parametres Dial it is kind of dial on telep...

Страница 6: ...uring TRH setting that incoming direction speaker and outgoing direction microphone are influence each other We recommend to dont set high volume in the begining of micro or speaker and via TRH set bo...

Страница 7: ...s possible choice from the current loop is powered Attention button is galvanic connect with source power of current loop and isolated from line by optocoupler In case powered current loop from teleph...

Страница 8: ...into loudspeaker Level from which volume with switch on direction from microphone doorphone setting trimmer TRH This setting interact level surrounding noise and setting gain of microphone MIC Progre...

Страница 9: ...voltage in Hang up status disconnect loop 20 60V during connection not depends on polarity when NLLW pick up active status on telephone line is cca 7 12V depends on line current which is in range 20...

Страница 10: ...e 10 1 3 5 Button and blocking connection BUTTON a BLOCK When telephone line is connected we need connect button only The button is connected to screw terminal mark BUTTON Look on picture 4 Picture 4...

Страница 11: ...ton is galvanic connect with source power of current loop and isolated from line by optocoupler In case powered current loop from telephone line is button galvanic connect with telephone line Picture...

Страница 12: ...puts for those indicators are isolated from other components and each from other as well The switchers are made until current 0 5A and voltage 50V On Picture 6 you can see examples of lamp indicator c...

Страница 13: ...of this voltage change before failure calling is activated INPUT is possible connecting up to 100m and is possible conecting moore butons switch on paralel or switch off buttons serial Control of type...

Страница 14: ...8 Connection of machine room communication 3WR When use in machine room modul PREPOJ you can see on picture 8 its connection From machine room to lift cabin must lead 3 wires Picture 8 Connection of m...

Страница 15: ...powering power 12 24V is possible and DC or AC voltage because telephone line has not enough power Screw 12V is isolated from other components and not depends on polarity Screw marks COM is share outp...

Страница 16: ...e 16 1 4 NLLW Installation The compact solution of NLLW enables easy installation into lift cabin panel Dimension and installation holes are descriped on picture 10 SPK MIC panel NLLW unit Picture 10...

Страница 17: ...three SPK MIC panels The lift cabin panel should be equiped by acoustic holes in microphone as same as speaker part It should be also provides by 4 screws M4 for fixing the SPK MIC panel The proper m...

Страница 18: ...lighting Command confirmation from phone 425 Dial DTMF Pulse Light off Call lighting x Notification of call ending 1275 lighting x Enter to programming mode from phone 850 Yellow lighting Programming...

Страница 19: ...ed It means when you programm numbers to all 6 position then progressivelly dial all 6 numbers When you erase number on position 3 then dial numbers on position 1 and 2 and returns back to position 1...

Страница 20: ...mber or all round of emergeny numbers then you have max 7 numbers The service calling is repeated in period 0 9 min programmable until succesfull call confirmation The repeated time between calls is p...

Страница 21: ...on box named PREPOJ and via connection of third wire telephone line has 2 wires And third is for NLLW controlling Wires connection is displayed on picture 8 page 15 The call is activated by picking up...

Страница 22: ...ametres The initial state for programming is signaled by programming tone and the guard will come back to this state always after time expiration 5 seconds even you started to program anything When pr...

Страница 23: ...line powering Procedure Connect the NLLW to the line Connect the NLLW with PC by KAB cable if PC serial port absent the USB COM reduction is to be used The NLLW will answer and LED light on the front...

Страница 24: ...Note Default 21 t nn Number nn in order p with confirmation t t call confirmation programm 0 1 only 0 confirmation OFF nn telephone number up 16 digits To programm other characters look on table Basi...

Страница 25: ...ers programmed in parameter 21 and 1 List of corresponding parametres 1 21 31 56 36 Parameter Value Note Default 33 i For failure calling are used also emergency numbers 0 i 0 emergency numbers are no...

Страница 26: ...position until empty or 6th position This is 1 sequence It might be repeated max 5 times List of corresponding parametres 1 Parameter Value Note Default 38 e Time of failure duration before failure c...

Страница 27: ...rameter Value Note Default 45 yyyyyy Confirmation character during dial in advance 66 yyyyyy confirmation character is numerals combination from 2 to 6 numerals List of corresponding parametres 1 21 2...

Страница 28: ...p always between rings It is 2 seconds after detection q th rings The number is adjustable from 1 to 9 List of corresponding parametres 44 Parameter Value Note Default 52 d Max call duration 2 d max t...

Страница 29: ...ks up the line and dialling the number range 1 5 sec This time is different for each PBX type but usually all PBXs works with time up 2 seconds List of corresponding parametres 8 85 Parameter Value No...

Страница 30: ...duration time ms range 1 0 it is 60 150ms m the time of space between tones is calculate insert number 5 x 10 space duration time ms range 1 0 it is 60 150ms f the time of Flash is calculate insert n...

Страница 31: ...ting for parametres 5x only 5 only Parameter 81 perform erasing of all numbers saved in memories of emergency service and failure call Parametres 83 85 perform selected default for parametres 3 5 only...

Страница 32: ...ng is switched off z 1 only tones pick up and hang up z 2 only other tones except pick up and hang up z 3 all tones they are switched on Parameter Value Note Default Ex 1 Ex 2 6 p polarity input buton...

Страница 33: ...cy call sequences 1 38 e The failure time duration before activation of failure calling 1 39 w Failure error call or Technical call 1 41 v Dial type v tone pulse 0 42 z Character to prolong a call 43...

Страница 34: ...rametres 5x only 5 only 9 E N D 5 Technical parametres 5 1 Elektrical parametres Parameter Value Conditions Min line current 18mA Line OFF HOOK Min line voltage 18V Line ON HOOK Line voltage when is N...

Страница 35: ...6 Emergency number position 3 Confirm 1 0 13 16 Emergency number position 4 Confirm 1 0 14 16 Emergency number position 5 Confirm 1 0 15 16 Emergency number position 6 Confirm 1 0 16 16 Service call n...

Страница 36: ...for relay switching from phone 48 2 Time of relay closing 49 2 Number of rings before picks up 51 1 Max call duration min 52 1 Time of button holding sec 53 1 Hanging up time when is redial sec 54 1 T...

Страница 37: ...Picture 11 Example of connection with LED blocking and failure is activated by voltage connection machine room communication...

Страница 38: ...TECHNOLOGIES s r o Jeremenkova 88 140 00 Praha 4 Czech Republic VAT CZ27577350 Company is registered in the Commercial Register administered by the Municipal Court in Prague Section C Record 116886 Ba...

Отзывы: