NLLW 50
– ‚User guide
26
List of corresponding parametres:
1 53
Parameter Value
Note
Default
36
c
Time of service call repeating
5
c
–
0
÷ 9
– unsuccesfull service call is repeated after time 0 ÷ 9 minutes. This
time is adjustable to repeated service call from more NLLW doesnt come
in same time.
List of corresponding parametres:
31 56
Parameter Value
Note
Default
37
d
Number of emergency call sequence repetation
1
d
–
1 ÷ 5
times is repeated dial of emergency numbers (button pressing).
Emergency numbers are dialled from first position until empty or 6th
position. This is 1 sequence. It might be repeated max 5 times.
List of corresponding parametres:
1
Parameter Value
Note
Default
38
e
Time of failure duration before failure calling is
activated
1
e
–
0
÷ 9
is time [sec] of permanent failure duration on input INPUT to be
activated failure calling
List of corresponding parametres:
22 33 34
Parameter Value
Note
Default
39
w
Failure (error) call or Technical call
1
w
–
0
Technical call - acoustic with indication
–
1
Failure (error) call - special beep, mute and without indication LED
4.3 Basic parametres
Parameter Value
Note
Default
41
v
Dial type
v
– tone / pulse
0
v
– dial type
v=0
DTMF tone dial
v=1
pulse dial
List of corresponding parametres
1 21 22