![Alpha InTec 50CS Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/alpha/intec-50cs/intec-50cs_installation-user-and-servicing-instructions_2905186020.webp)
INS
TALL
ATI
O
N
US
ER
MAINTEN
AN
CE
20
Alpha Intec 50CS
2.14 PARAMETERS ANd INFORMATION
MENU (REFER ALSO TO FIG. 2-1).
By pressing the button 'D' it is possible to access
a menu divided into three main parts:
- 'M1' - Information.
- 'M3' - Customisations.
- 'M5' - Configurations, menu reserved for the
engineer and for which a password is required.
Turn the central heating temperature selector
switch (item 3) to scroll through the menu
items.
Press button 'D' to access the various levels of
the menu.
Press button 'C' to go back one level.
Level 1
Button
Level 2
Button
Level 3
Button
Description
M1
D
C
P11
D
C
View the management software version of the boiler P.C.B.
xx = software display version
yy = ignition control software version (burner control)
zz = P.C.B. software version
P12
View the total operating hours of the boiler
P13
View the number of burner ignitions
P14
(with optional
external sensor
present)
- - -
(without optional
external sensor)
D
C
P14/A
View the current external temperature (optional external sensor used)
P14/B
View the minimum external temperature recorded (optional external
sensor used)
P14/C
View the maximum external temperature recorded (optional external
sensor used)
RESET
D
x
select
C
By pressing button 'D' the MIN and MAX temperatures measured are
zeroed
P15
D
C
No display on this boiler model
P17
View the fan speed
P18
The value displayed does not affect this model
P19
View the last 5 events that caused a boiler shutdown. The sequential
number from 1 to 5 is indicated in the display (position 6) with the
relative error code in postion 7.
By pressing button 'D' repeatedly it is possible to view the operating
time and the number of ignitions at which the anomaly occurred
Information Menu.
This menu contains various information relative to the boiler operation:
Customisation menu.
This menu contains all
options that can be customised. (The first item
of the various options that appears inside the
parameter is that selected by default).
Important:
if the international language is to be
restored (
A1
), proceed as follows:
- press button 'D' to enter the configuration
menu.
- turn selector switch '3' to
'PERSONAL'
.
- press button 'D' to confirm.
- turn selector switch '3' to
'dATI'
.
- press button 'D' to confirm.
- turn selector switch '3' to
'LINGUA'
.
- press button 'D' to confirm.
- turn selector switch '3' to
'A1'
.
- press button 'D' to confirm.
At this point the international items indicated in
the menu tables appear on the display.
Level 1
Button
Level 2
Button
Level 3
Button
Level 4
Button
Description
M3
D
C
P31
D
C
AUTO
(default)
D
x
select
C
The display lights up when the burner
is ignited and when the controls are
accessed, it remains on for 5 seconds after
the last operation performed
ON
The display is always lit up
OFF
The display only lights up when the
controls are accessed and remains on for 5
seconds after the last operation performed
P32/B
D
C
ITALIANO
D
x
select
C
All descriptions are given in Italian
A1
(default)
All descriptions are given in
alphanumerical format
P33
D
C
OFF
D
x
select
C
In winter mode, by activating this
function it is possible to activate the
central heating function even if the
optional environmental thermostat (TA)
is out of service
ON
RESET
D
x
select
C
By pressing button 'D' the customisations
made are zeroed, restoring the factory ser
values
Содержание InTec 50CS