type = tiMEr?
CYC
xxxx
ConF
xxxx
On.d
xxxx
OF.d
xxxx
(Number
of
cycles)
(Timer
configuration)
(Timer
on-delay
setting)
(Timer
off-delay
setting)
This value decides the number of
cycles for timer output.
Range: 0000 - 9999
This option configures the timer
operation.
Options: En, d.En
This value decides the on-delay for
timer.
Range: 0001 - 9999
This value decides the off-delay for
timer.
Range: 0001 - 9999
quit
Quit screen for timer settings.
(Quit
screen)
yes
yes
no
type = rEMotE?
quit
(Quit
screen)
Quit screen.
yes
yes
no
D2
D1
D3
D4
or
D3
D1