p. Holiday Mode
During winter mode function it is possible to deactivate both the hot water and central heating for a defined number of days (1 to 99). When
the set number of days has past normal function will resume.
When the holiday mode is set a flashing
will be displayed and the number of days it is enabled for.
To set the holiday mode press
OK
then the + button until HOLIDY appears then
OK
to accept.
Off
will be displayed and by pressing the +
button the number of days can be set, press
OK
then
ESC
once to get to main menu and the
symbol and set number of days will flash
at the bottom of the screen.
This function can be deactivated by pressing the
button.
In the event of remote telephone activation the Climatic controller will revert back to normal operation omitting the holiday program.
NOTE; the frost protection function is still active during holiday mode.
q. Legion (anti-Legionella function)
The anti-Legionella function raises the temperature of the hot water storage cylinder to the maximum boiler set temperature for 20 minutes to
kill Legionella bacteria.
It is possible to set this function once a day at 2am (ON 24H), every Monday at 2am (ON 7 DAYS) or deactivate it (OFF standard function).
NOTE; this function must only be activated when a cylinder is present and a thermostatically controlled blending valve should be fitted to the
cylinder hot water outlet.