j. Faults Diagnostics and Errors
The Climatic remote control continually controls the functioning of the boiler and signals any anomalies, stating the corresponding error code
on the display.
The error codes are listed in the boiler installation manual.
If a fault occurs it will be displayed as “ERR-XX” where the “XX” represents a number that identifies the code as well as a flashing
symbol.
The climatic also checks its own functioning state, indicating any malfunction.
Code Description
ERR>CM (Climatic Display)
Communication error between the Alpha Climatic remote controller or receiver and the boiler.
ERR>TP (Climatic Display)
Error in reading the room temperature or value measured off scale (below 0ºC or over 50ºC)
E51 (Boiler display)
Communication error between the Alpha Climatic remote controller and receiver. (Climatic RF only)
k. Reset Errors
In the event of a resettable boiler lock out
RESET
will flash on the display. By pressing and holding the reset button (ref 2 fig 4) for 5
seconds, it is possible to reset the boiler.
It is possible to reset the boiler up to 5 times then one hour must elapse until one more attempts can be made.
l. Reset Climatic Remote Control
By pressing the reset button (ref 4 fig 4) the climatic remote control hardware can be reset without losing the user setting, such as time, date
and timed programmes.