8
There is also activated different voice message during
activation and call picked up - „Attention it is test of
connection“. When call is hanged up then is activated standard
message „Call is ended“. Phone numbers might be the same
in both sets (MASTER and TEST).
In the same time might be beside or instead testing call tested
local acoustic connection (GLWV – cables – ReMic speaker –
ReMic microphone – cables GLWV). During test is activated
message „Sound test – one, two, three, four – end.“. The
GLWV measures change of signal level identified by MIC
between stand by mode and sound level during message
playing. The testing will not be correctly evaluated when
surrounding noise is too high – any or very small change
signal level. The test can discover not connected ReMic or
short circuited MIC.
In the same time might be send SMS TEST including info:
Firmware version
Back up ACU voltage
Power supply voltage
Setup time and date in GLWV
GSM operator
GLWV temperature
Number of service visits with date of last one (1)
Input status IN1
Blocking status (input IN2)
Relay status
Date and time of last emergency call (2)
Result of acoustic test (3)
1) When „Service OK“ mode was setup
2) When was setup „Emergency“ mode it is shown, date
and time last mode activation. When mode is
deactivated (remotely or locally) it is signalized by „- -„
3) When is setup Acoustic test as same as sending SMS
TEST then acoustic test is firstly made to be mentioned
current status in SMS TEST.