1
The GSM lift watch is designed for emergency call from lift
cabin to first aid ( service department, security, etc..).
The unit is developed up directive EN 81-28+AC:2019-04 and
EN 81-70.
Basic technical parameters:
Power supply
8 to 30V ss, 50 to 500mA (up operation)
Integrated ACU
Li-Ion 2000 mAh - cca 12h of operation in
stand by
GSM network
900/1800MHz
Ext. signalization
LED or light 12V (24V) max.100mA
Inputs
2x – 1x calling blocked, 1x universal
Relay contact
1x 24V/100 mA
PC interface
mini USB
Basic unit 131 x 111 x 38,5 mm
ReMic module
110 x 78 x 38 mm
ReMicAS1 module 135 x 66 x 22 mm
Functionality:
At installation place is not necessary phone line
availability
Possibility of Voice communication for cabin, shaft and
machine room (ReMicA1, ReMicAS1,
PREPOJ) – simultaneous connection of all units with
operator/ connection machine room – shaft – cabin only
Changeable back up Accumulator (ACU)
User friendly installation as same as settings
(for start just saving 1 phone number on the SIM card)
After activation (button push) progressively call up 7
numbers (MASTER1-7) saved on the SIM card.
Other numbers are restricted to call.
Automatic verification call once for 1-9 days to TEST
number(s) (TEST1-7) saved on the SIM card
Adjustable emergency call blocking (delay/ prolong of
blocking) - if the call button is held for more than 30s,