[x=0-9]
0 – function is off
WRITE
PAR TSHIFT:x
Move service call start from midnight [0-
9] x2 hours (i.e. 8= shift 16 hours)
0
WRITE
PAR TMODE:x
Type of performed tests
x=0 – no test
x=1 – service call for TESTx numbers
x=2 – SMS TEST (STATUS)
x=4 – acoustic connection test
all bit combination possible for example
x=7 – all tests activated
x=6 – SMS and acoustic connection
test
1
WRITE
PAR WBLOCK:x
time x sec. Of IN2 port closing
necessary for blocking start
[x=0-9]s
1
WRITE
PAR BLOCK:xx
Blocking duration xx sec. After IN2 port
is opened [xx=00-99]s
01
WRITE
PAR ACALL:x
Time x sec. Of button press to make
emergency call
[x=0-9]s
3
WRITE
PAR WCALL:xx
time xx sec. Waiting for connection
before dialling next number in order
[xx=10,20,30..90] sec.
20
WRITE
PAR EXMODE:x
Extended mode
x=0 – off emergency mode and service
mode
x=1 - on emergency mode, service
mode is off
x=2 - on service mode, emergency
mode is off
0
WRITE
PAR RL1MOD:x
Relay mode
x=0 – SMS mode, control by SMS
x=1 – ECALL mode (relay is closed
for time “emergency”
x=2 – camera mode (close by pick up
open by hang up)
x=3 – lighting mode (close by pick up,
stay closed for „closing time“
after hang up
x=4 – button mode, close for time
„closing time“ after button
press
x=5 – „service” mode – after IN1 port
0