21
Subject to change without notice | 83059100fUK – Translation of the original operating manual | ait-deutschland GmbH
LWV 122R3
Performance curves / cooling
Keys:
“
KW
Volumetric flow, cooling water
Temp
WS
Heat sink temperature
Temp
KW
Cooling water temperature
∆pmax
max. free pressing
Q0 min/max
min./max. cooling capacity
Pel min/max
min./max. power consumption
823291b
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
10
15
20
25
30
35
40
45
Temp
WS
[
°
C]
Q0 min/max [kW]
7°C
18°C
0
1
2
3
4
5
6
7
8
9
10
10
15
20
25
30
35
40
45
Temp
WS
[
°
C]
Pel min/max [kW]
7°C
18°C
5
10
15
20
25
30
35
40
5
10
15
20
25
30
35
40
45
T
emp
KW
[C
°
]
Temp
WS
[
°
C
]
0,00
0,05
0,10
0,15
0,20
0,25
0,30
0
0,5
1
1,5
2
2,5
3
“
WS
[m³/h]
∆pmax [bar]