3. Open the strap tensioner and turn the hook on the
base plate through 90°.
4. Attach the swelling tape to the louvre grille and
blind cover by applying it around the edges and
then sticking it in place.
Heat pump installation instructions
5. Remove the two styrofoam crosspieces.
6. Install the blind cover and the louvre grille.
807xxx
Attach the louvre grille to the air outlet side (right
or left)! The blind cover on the opposite side.
7.
Attach rear wall and screw firmly into place.
Heat pump installation instructions
5.5 Installation of air ducting
Air discharge to right or left
Left air discharge
Right air discharge
Ers. d.
Ers. f.
E
D
C
B
A
4
3
2
1
Air duct installation instructions
Wall duct installation instructions
5.6 Attach side walls, rear wall and
cover
Heat pump installation instructions
1. Fasten rear wall.
2. Hang side walls from above. Fasten at the front
with a screw in the middle. Fasten with 2 screws
at the bottom.
3. Fit cover and screw into place.
6 Hydraulic installation
NOTE
If an existing system is being replaced, the
old vibration decoupling may not be reused.
NOTE
The heating circuit must be flushed thoroughly
before connection to the heating system.
ATTENTION
Damage to the copper pipes due to unacceptable
loading!
►
Secure all connections against twisting.
Cross-sections and lengths of the pipes for the
heating circuit are adequately dimensioned.
The free pressing of the recirculating pump
produces at least the minimum throughput