10
We reserve the right to modify technical specifications without prior notice.
UK830510/191106
© Alpha-InnoTec GmbH
pull lower facing panel upwards and outwards, de-
tach and set securely to the side...
on the back of the unit, remove the sealing grom-
met...
Insert the pipes through the holes in the frame on
the switch cabinet side (= operator side)...
1 Holes in the frame
2 Inserted pipes
make sure that pipes do not damage cable assem-
blies and components in the unit. Guide pipes care-
fully past cable assemblies and components in the
unit...
Guides pipes through the marked openings on the
back side of the unit...
CautIon.
Do not damage the hydraulic connections
under any circumstances.
CautIon.
Do not tilt the unit more than a maximum
of 45° (in any direction).
lifting the unit with pipes
only possible with the lw 250(l) and lw
320h(l)!
The lW 250(l) and lW 320H(l) units can be lifted with
3
/
4
" and/or 1" pipes (provided by customer) that are suit-
able for the weight of the respective unit. Special holes
are provided in the frame for this purpose.
Remove lower facing panels on the switch cabinet
side (= operator side) side of the unit. To do so,
loosen quick-release screws. Turn counter-clock-
wise 90°...
1 quick-release screws
2 lower facing panel