background image

33

-F1
3

A1

A2

-K1
3

-F1
2

-F

11

-F

10

A1

A2

IN4 IN3

T

B1

E

ner
gy

 s

upp
lier

 c

ont
ac

t; c

los

e

on 
rel

eas
e;

 br

idge 

if no 
bl

oc

king

 int

e

rv

al

E

V

U2

NTC9

E

V

U

1

H

eat
ing 
cir

cui

t c

irc

ulat

ing

 pum

p

IN1

NTC7

3

A5

X

10

TA

-X

5

-2

T

BW

O

UT
3

N

E

ner
gy

 s

uppl
ier

 c

ont
ac

t; 

clos

e

d on 
rel

eas
e;

 br

idge
 if 

no

 bl

oc

king

 int

e

rv

al

N

GND7

5

N

Out4

GND8

Out7

In

fo

rm

at

io

n

 o

n f

us

es

 c

an

 b

e f

ou

nd

 in

 th

e t

ec

hn

ic

a

l d

at

a

X

10:
L,

N

,P

E

L

TBW

GND9

N

Out1

F1
0

AIN2

H

ot

 w

a

ter

 gauge

/ther
m

os

tat

3

O

UT
4

O

U

T6

C

ut 

out
 c

ont

rol

ler

 uni
t

-X9

M

F1
1

NTC8

C

ut

 o

ut

 a

ux

ilia

ry

 heat

ing 
1

P

ow
er

 s

uppl

y c

ont
rol

ler

 23

0V

PE

ZI

P

S

ens
or

 m

ix

ing

 c

irc

ui

t 1

F

unc
tio

n

-X

10

Out3

Out5

Out2

A5

AIN1

T

er

m

in

al 

str

ip 

in 

sw

itc

hbox

 of

 hea
t pum
p;

 N

/P

E

 di

str

ibu

tion

 for

 ex

ter

nal
 2

30V

 u

ni

ts

L1

C

ont
rol

 s

ignal

 of

 ad

d

itional
 heat

 g

ener

at

or

 2 

(al

te

rnat
iv

is

 gener

al

 m

al

func
tion)

NT
C5

3~N/PE/400V/50Hz

A2

ZW
2

U

K

83
1186

3-

pol
. C

u

t out
 c

om
pr

es

sor

; A

ttent
io

n:

 R

ig

ht

-han
d

 ro

t. f

iel

is

 m

anda

tor

y!

PE

L1

TRL

5

L1

BU
P

AGP1

ZW
2

5

E

xter

nal
 s

ens
or

A

ir

 w
a

te

r in
s

id

e

 1

6

 -

 1

6

 k

W

-X
4

F1
2

NT
C8

A

ux

iliar

y c

irc

ul

at

io

pu

m

p

ZW
2

IN2

1

Q1

NT
C2

A1

Na
m

e

M

E

V

U

O

UT
8

IN3

NTC1

O

UT
1

C

ont
rol

ler

 boar

d;

 A

ttent
io

n:

 I-

m

ax

 =

 6

A

/23

0V
A

C

TA

GND2

AGND2

GND4

TB1

C

ont
ac

tor

 el

e

ctr

ic

 he

at

ing

 el

e

m

ent
 ho

t w

at

er

 or

 buf
fer

 tank

-X

3

-2

IN2

F

P1

IN4

AOUT2

E

xter

nal
 ret

ur

sens
or

A3

A3

A1

MI

S

T

R

L.

ex

t

M

Z

1/

M

IS

B

UP

-X

3

-1

Out6

H

U

P

IN5

S

T

B

 F

B

H

S

af

et

y t

em
per
at

ur

lim

iter

 for

 under

floor
 he

at

ing

, br

idge 

if not
 av

ai

labl
e

ZI

P

ZU
P

Z

W

2/

S

S

T

O

UT
5

NTC5

TR
L

M

A

1/MI

S

NTC4

F

P1

2

IN1

NTC2

L

IN5

H

ot

 w

a

ter

 or

 buf
fer

 s

tor

ag

tank

1~N/PE/230V/50Hz

NTC6

S

ub-
di

str

ibut
ion 
uni
t int

er

n

al

 ins

tal

lat

ion

GND1

O

UT
7

A2

NT
C3

-X

5

-1

1

kW

T

er

m

in

als

AGND1

H

ot

 w

a

ter

 c

irc

ul

at

in

pum

p/

sw

itc

hi

ng 
val

ve

cir

cul

at

ion 
pu

m

p

F1
3

C

ut

 o

ut

 a

ux

ilia

ry

 heat

ing 
2

AOUT1

K

13

2

AGP2

NTC3

GND3

T

er

m

in

al

 s

trips

 on 
con

trol

le

r boar

(s

ee 
sti

ck

er

)

3~N/PE/400V/50Hz

HUP

Q6

ZW
2

N

GND5

OU
T

2

GND6

T

er

m

in

al

s i

n heat
 p

um

sw

itc

hbo
x

P

um
p f

or

 m

ix

ing 
cir

cui

t 1

R

et

ur

sens
or

-X1
0

C

har
ge

/di

sc

har

ge/
cool
ing

 m

ix

e

r 1 

open

X

3-1

-X

9

TRL.ext

Le
g

e

n

d:

Z

UP

N

T

C4

Out8

3~N/PE/400V/50Hz

C

har
ge

/di

sc

har

ge/
cool
ing

 m

ix

e

r 1 

clos

e

d

2

5.04
.20
1

4

1

A

chi

m

 P

fleg
er

10X

623 

- 1

0X

6

24

;

1

/1

A

ch

im

 P

fle

ge
r

11

.02
.20
14

T

er

m

inal
 di

agr
am

 LW
I H

/V

8311

86

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

-

P

E

P

 001
/2

013

B

l v

o

n A

n

z

N

am
e

D

at

u

m

Z

us

ta

nd

B

la

tt-N

r.

B

ea
rb.

D

at

u

m

Ä

nde
ru

n

g

Subject to change without notice.
83054800bUK – Translation into English of the original German operating manual  ait-deutschland GmbH Subject to change without notice.

Subject to change without notice.
83054800bUK – Translation into English of the original German operating manual  ait-deutschland GmbH

Terminal diagram

Содержание LW 160H/V

Страница 1: ...t to technical change without notice 83054800bUK Translation into English of the original German operating manual ait deutschland GmbH HEAT PUMPS Operating Manual Indoor installation AIR WATER UK LW 1...

Страница 2: ...e parameters for the respective model This operating manual is intended only for persons assigned to work on or with the unit Treat all its constituent parts confidentially They are protected by copyr...

Страница 3: ...CIRCULATION PUMP 17 BUFFER TANK 17 WATER HEATING 17 HOT WATER TANK 17 ELECTRICAL CONNECTION WORK 18 FLUSHING FILLING ANDVENTING THE SYSTEM 19 Water quality of the fill and make up water toVDI 2035 19...

Страница 4: ...to current state of the art standards all relevant DIN VDE regulations and all relevant safety regulations Every person who carries out work on the unit must have read and understood the operating man...

Страница 5: ...wage gases flue gases can cause damage to the heat pump which can result in complete failure irreparable total damage to the heat pump Can be installed near the coast CAUTION In the air outlet area th...

Страница 6: ...ng is mandatory for air water heat pumps Heat metering for brine water and water water heat pumps only has to be installed for a flow temperature 35 C The heat metering must record the total thermal e...

Страница 7: ...checked and cleaned as necessary but at least by qualified personnel heating or cooling system fitters It is best to sign a maintenance agreement with a suitably competent company It will arrange for...

Страница 8: ...UP 25 85 PWM What to do first Check the delivery for outwardly visible signs of damage Check to make sure that the delivery is complete Any defects or incorrect deliveries must be reported immediatel...

Страница 9: ...410A 0 44 kg m Technical data scope of supply overview General unit data section Minimum room volume Refrigerant capacity kg Limit value kg m NOTE If several heat pumps of the same type are installed...

Страница 10: ...nd secure it against slipping Put down the unit at the place of installation Make sure that the unit s baseframe is in full contact with the surface of the floor Remove the tube handles If the electri...

Страница 11: ...wer facing panel on the fan side and remove it from the unit To do this undo the quick release screws Turn through 90 to the left 1 Quick release screws 2 Lower facing panel Pull the lower facing pane...

Страница 12: ...rods and re attach all facing panels to the unit INSTALLATION Place the unit on a stable solid and horizontal preferably structural sound insulated surface Make sure that the floor is designed for the...

Страница 13: ...by bricking around the penetration NOTE Install wall penetrations 1 cm above the finished external fa ade 1 Outside of the building masonry 2 Inert the wall penetration in the masonry 1 cm above the f...

Страница 14: ...tion the air duct on the respective air opening of the air inlet side At the air inlet side of the heat pump hook 4 of the tension springs supplied in the holes provided for this purpose Hook the tens...

Страница 15: ...FRAME TRIM Screw the frame trim onto the wall penetration on the air inlet and air outlet side NOTE The frame trim does not fulfil any technical function it is merely for establishing a visually attr...

Страница 16: ...n the unit For details on how to position the connections refer to the dimensioned drawing for the respective unit model 8 x NOTE Attach the weather louvre if the wall penetration is above ground leve...

Страница 17: ...he hot water tank must be dimensioned so that the heating capacity of the heat pump is transferred with minimum temperature drop We offer a variety of hot water tanks for you to choose from They are o...

Страница 18: ...at least 3 mm contact spacing to IEC 60947 2 Residual current circuit breaker type A is sufficient Technical data scope of supply overview Electrics section NOTE In units with integrated electric heat...

Страница 19: ...limescale deposits form on the heat transfer surfaces of the heating Efficiency falls and energy costs rise A rule of thumb is that 1 millimetre of limescale deposit causes an efficiency loss of 10 In...

Страница 20: ...e if the system is operated with salty i e softened water Even drinking water softened beforehand contains dissolved corrosive salts which due to the use of different materials in the heating system a...

Страница 21: ...at the rear of the control unit which are used to hook the control unit onto the front panel of the unit Hook the control unit s hooks into the openings of the front panel either in the upper or lower...

Страница 22: ...delivered condition so that the control unit can be inserted in the upper openings of the front panel If the control unit has been inserted in the lower openings of the front panel you must remove the...

Страница 23: ...ual the electrical installation work has been completed properly The power supply for the heat pump must be equipped with an all pole automatic circuit breaker with at least 3 mm contact spacing to IE...

Страница 24: ...low valve menu item is pre set to No The overflow valve setting function is deactivated Control signal UWP is the display of the currently re quested pump delivery in Actual flow is the current flow m...

Страница 25: ...us dem W rmepumpenregler ausgelesen werden Volumenstrom Spreizung 2000 1 2000 2 2000 3 2000 4 2000 5 2000 6 2000 7 2000 8 2000 9 0 5 10 15 20 25 1 2 3 4 5 6 7 8 9 Heizleistung in kW Spreizung in K Ein...

Страница 26: ...l pressure m h 4400 Maximum external pressure Pa 25 Heating circuit Flow rate pipe sizing l h 2000 Free compression Pressure loss Flow rate bar bar l h 0 513 0 157 2000 Control range circulating pump...

Страница 27: ...35 C 50 C 65 C 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 0 5 1 1 5 2 2 5 3 m h p bar Bezeichnung Seite 1 D ring 05 09 2014 823233a Datei 823233a Leistungs Druckverlustkurven LW 160H AV xls nd M Erste...

Страница 28: ...a innotec de D 95359 Kasendorf Industriestra e 3 Alpha InnoTec GmbH Schutzvermerk nach DIN 34 beachten Ers d Ers f A B C D E F 4 3 2 1 Benennung Ma bild LW 140 180 LW 819355 a Zust nderungstext PEP 02...

Страница 29: ...ories Rain louvre 1045x1050 KA Condensate drain G Detail of installation in the light well 7 provided on site by the customer Light well with water outlet min free cross section 0 75 m Tipping dimensi...

Страница 30: ...Accessories Air duct bend 900x1050x1450 LR Air direction 5 Installation above ground level Accessories Weather louvre 1045x1050 LRR Air direction of units with fan right hand side LRL Air direction of...

Страница 31: ...units with fan right hand side LRL Air direction of units with fan left hand side BS Operating side 6 Installation in the light well Accessories Rain louvre 1045x1050 FWS Finished wall thickness KA C...

Страница 32: ...ground level Accessories Weather louvre 1045x1050 LRR Air direction of units with fan right hand side LRL Air direction of units with fan left hand side BS Operating side FWS Finished wall thickness...

Страница 33: ...ntactor electric heating element hot water or buffer tank X3 2 IN2 FP1 IN4 AOUT2 External return sensor A3 A3 A1 MIS TRL ext MZ1 MIS BUP X3 1 Out6 HUP IN5 STB FBH Safety temperature limiter for underf...

Страница 34: ...y heating Compressor 1 Operating materials Line reactors M1 Q1 ZW1 Terminal in switch box heat pump ws 3 ZW1 PE 2 3 VD1 5 br ge Q6 sw 3 N PE 400V 50Hz E22 VENT sw 1L1 1L2 1L3 1N PE power supply additi...

Страница 35: ...ion Q6 K50 K22 K23 Contactor for auxiliary heating Defrosting valve L N PE power supply controller K50 EXL High pressure switch 230VAC Q1 1 N PE 230V 50Hz Controller board cooling circuit Operating ma...

Страница 36: ...EVI UK817395 TVL Suction sensor condenser TWE HD K50 R4 Operating materials B10 K50 Flow sensor Controller board cooling circuit R2 Heat source input sensor Function EVI 05 03 2014 3 Achim Pfleger 3...

Страница 37: ...R6 A A GND LIN bus K30 12V LIN Modbus B K30 GND LIN 12V M6 Return sensor Function Heating pump energy efficiency TRL Controller board Attention I max 6A 230VAC Operating materials UK817395 HUP Legend...

Страница 38: ...8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Bl von Anz Name Datum Zustand Blatt Nr Bearb Datum nderung Subject to change without notice 83054800bUK Translation into English of the...

Страница 39: ...LW 160H V 100 623 2006 42 EG LW 180H A 100 540 100 542 100 543 100 544 100 545 100 546 LW 180A LW 251A LW 310A LW 100H A confirms that the following designated device s as designed and marketed by us...

Страница 40: ...DE ait deutschland GmbH Industriestrasse 3 D 95359 Kasendorf E mail info alpha innotec com www alpha innotec com...

Отзывы: