background image

DEHUMIDIFIERS

-1

1

-

Preparing the Unit for Use

( 1 )  The position will be placed in the following figure the machine can take advantage of 

machine performance.

( 2 ) In order to avoid the repeated water tank caring,It is in strongly recommendation that 

to extend the draining to ground if this unit would in long term running.if the outlet pipe get 

wrapped or deflated,it would resulte bad water follow and even cause dead machine. 

1. The tank cover open

Vias

( 3

 

)  Insert the power cord to matched socket safely and reliably

≥≥

≥≥

2    

    

through the Vias on

 

    

Base and connect

 

    

it to the water pipe 

    

which been fixed on

 

    

water collector

Put External pipe 

DEHUMIDIFIERS

Maintenance and Repair

-1

2

-

a. out of the filter

1. Exterior Cleaning

Use a soft, slightly damp cloth to wipe the plastic body.

2. Filter cleaning

1)  Open the air intake frame

2)  Out of the filter

b. Clean the filter

Using  a  vacuum  cleaner  to  gently 

absorb  dust  filter  surface  ,  if  the  filter  is 

very dirty, with a brush to brush off surface 

dirt.

Maintenance

Warning-Always Unplug Unit Prior To Performing Any Maitenance! 

1.Electronic Control Maintenance

 The fixing screws on the rear panel of the machine is removed

ALORAIR

ALORAIR

ALORAIR

Содержание Ironmen 50L

Страница 1: ...Ironmen 50L E mail sales alorair com Add North Carolina USA Installation and Operations Manual ALORAIR ALORAIR Registrate by scanning...

Страница 2: ...f purchase so you can identify your unit when seeking assistance NOTE data label on back of unit includes serial number DEHUMIDIFIERS Contact your installing contractor Email sales alorair com please...

Страница 3: ...ute prior to shutting off 2 Purificaction Button P Press air purification function is activated the compressor does not work after entering the mode the fan work timing temperature scale and set the h...

Страница 4: ...nd humidity On the second line Job T working time and Humidity Setpoint are displayed on an alternating basis I n l e t 3 2 7 6 The contents of the second line alternateevery 10 sec 5 DEHUMIDIFIERS or...

Страница 5: ...e t t i n g 3 5 1 The Humidity Setting Humid a Press the Menu M button The screen shows b Press the M button until Humid is flashing Press OK to select this option The screen shows 8 Operation and Di...

Страница 6: ...then turn off 3 Cycling Timer T I O Selection The third selection T I O lets you set up the machine to cycle on and off during a specific time frame For example you could set the unit to run 8 hours a...

Страница 7: ...socket safely and reliably 2 through the Vias on Base and connect it to the water pipe which been fixed on water collector Put External pipe DEHUMIDIFIERS Maintenance and Repair 1 2 a out of the filte...

Страница 8: ...e from air inlet or air outlet No Airflow Unit is not level Place unit on flat surface in vertical orientation Place unit on flat surface in vertical orientation Loud Unusual Noise 1 3 Trouble code E1...

Страница 9: ...labor including but not limited to labor to remove and or reinstall any defective part refrigerant or piping Customer may elect to have unit fixed locally in which case required replacement parts will...

Отзывы: