UE Systems Ultraprobe 401 Скачать руководство пользователя страница 1

Version 1 

 

 

 

 

 

 

Ultraprobe 401 

Digital Grease caddy Pro 

Instruction Manual 

 

 

 

 

 

 

 

 

 

 

Содержание Ultraprobe 401

Страница 1: ...Version 1 1 Ultraprobe 401 Digital Grease caddy Pro Instruction Manual...

Страница 2: ...1 Digital Grease Caddy Pro 3 Mounting the 401 Digital Grease Caddy to Grease Gun 5 III Setup 5 IV Getting Started 5 V Display Panel Screens and Functions 6 Setup Menu Screens 8 VI Other Features 13 Ul...

Страница 3: ...nloading of bearing data it lets users know when to stop adding lubrication as well as provide data of lubrication history that adds to analysis of bearing condition to prevent premature failure II Ma...

Страница 4: ...12 Display panel 13 BNC connector for magnetic mount probe 14 Recharge Jack 15 LED flash light 16 SD Card slot C Grease Gun Mounting Kit 17 Open clamp end 18 Clamp knob 19 Grease gun mount foot 20 Gre...

Страница 5: ...e operational features a On Off Button Press the On Off button 10 to turn the instrument on To turn off press and hold the button again b Sensitivity Spin and Click dial 11 use this dial to store data...

Страница 6: ...y 1 Display 2 Setup Menu STORE record To enter and use any of these Functions a Click the Sensitivity dial until the Function Bar blinks b Locate the desired Function menu by spinning the Sensitivity...

Страница 7: ...nfo Function Bar Screen Contains SD card information Spin to a feature click to use 1 Delete all files Click to enter spin to yes 2 Free space and info Click to enter 3 Display files To exit push and...

Страница 8: ...the Ultraprobe on power up c On power down off all data and WAV files are stored on the SD card d The Add Remove SD Card function allows users to change the card while the unit is on e While the powe...

Страница 9: ...y dial to select and spin it to on C Then click the sensitivity dial to set D To exit press and hold the sensitivity dial 4 Instrument Set Up Press to enter The selections are Manual and Auto Spin to...

Страница 10: ...desired frequency The frequency range is 20 kHz to 100 kHz 8 Frequency Adjust This feature allows the user to change frequencies between 20 kHz and 100 kHz in one kHz steps 9 Display Response Click t...

Страница 11: ...are three alphanumeric spaces spin to the left or right select a number or letter click to move between the three entry blanks Click and hold to set and exit 12 Set Time and Date Click to enter Spin t...

Страница 12: ...screen 15 DB Scale Type Select The choices are Relative and Offset 16 dB Offset Value Click to enter Spin for values 1 10 Spin to the right for values 1 40 Click to set and exit 17 Battery Level Click...

Страница 13: ...blinks 2 Spin the sensitivity dial to the preferred record number 3 Click firmly to set the cursor will move to the function bar 4 If Store Record is showing on the function bar press to store 5 If st...

Страница 14: ...tton Each click will equal one stroke d When through press and hold the sensitivity dial to store the record 2 Using with the Before and After function a To use this feature go to set up menu and sele...

Страница 15: ...d OSHA standards Frequency Response Peak response centered around 38 kHz Response Time 10 ms Display 128x64 LCD with LED backlight Operating Temperature 32oF to 122oF 0o to 50o C Relative Humidity 10...

Страница 16: ...d further support Want information regarding products or training Contact UE Systems Europe Windmolen 20 7609 NN Almelo NL e info uesystems eu w www uesystems eu t 31 0 546 725 125 f 31 0 546 725 126...