b.Press the Menu key unit TempU flashes.  Press OK to select.

c. The screen shows:T.on,T.off,T.I/0,R

“T.off” – Unit will stop when timer expires

“T.I/O”  –  Unit  will  cycle  “on”  and  “off”  based  on  the  set  time.    If  unit  is  off,  the 

cycling will start with unit “off”.  If unit is on, the cycling will start with the unit “on.”

d. Press the menu key, move into cursor to function you prefe.

T.on” – Unit will start when timer expires

T

i m e

O n
O

R

f

f

0

0

0

0

1) Start Time (T.on Selection)

a.Press to confirm key.The screen runs as follow, the first 00 positions (flashes) at the same 

time.

b.Press Up and Down key, the first position number from 00-24 variety, choose an hour 

numberc. Press to confirm key to make selection the number.

d.After,  the  next  number  position  automatically  flashes(minute  position).    Once  the 

correct time is displayed, press to OK key to make selection the number.

e.The OFF button will now flash. Press OK one more time, the OFF will switch to ON and 

the timer is now set.

a. Press the M button until the T.off button is flashing.  Press OK to confirm.

b. Set timer as above.

2) Shut Off Time (T.offSelection).  Unit will run for designated time and then turn off.

3) Cycling Timer (T.I/O Selection)

The third selection, T.I/O, lets you set up the machine to cycle on and off during a specific 

time frame.  For example, you could set the unit to run 8 hours a day and remain off the other 

16 hours.  Note:  You are selecting on and off periods of time, not set clock times.

-9

-

DEHUMIDIFIERS

9.Handlebar Mounting

Handle rotates 180 

°

, after aligning with locating pin holes will be fixed.

The locating pin is inserted and fixed

a. Press the M button until the T.I/O selection is flashing.  Press OK button to select.

b. Use the up and down arrows to adjust the hours and minute of the first cycle.

c. Use the M button to move from 1st line of display to second and adjust second time 

period with up and down buttons.

d. Press the OK button to confirm the time.  (Flashing OFF will turn to ON).

( 3 ) Temperature scale set

This selection allows you to switch the machine from displaying temperature in degrees 

Celsius to degrees Fahrenheit.

a. Press the menu key.The screen shows:Humid,Timer,Tempu, R.

H

u m

i

T

i

m e

r

T

e m p

R

d. Press the menu key to move the cursor to the ℃ on/offor ℉ off/on(flashes).

e. Press to confirm key.  The on/off status of C and F will exchange.

T

e m p

R

S

e

t

t

i

n

n

g

O

O

f

f

o

F

b.Press the Menu key unit TempU flashes.  Press OK to select.

c. The screen shows:Celsius degree℃ on/off and Fahrenheit degree the ℉ off/on.

-1

0

-

Содержание Ironmen 50L

Страница 1: ...Ironmen 50L E mail sales alorair com Add North Carolina USA Installation and Operations Manual ALORAIR ALORAIR Registrate by scanning...

Страница 2: ...f purchase so you can identify your unit when seeking assistance NOTE data label on back of unit includes serial number DEHUMIDIFIERS Contact your installing contractor Email sales alorair com please...

Страница 3: ...ute prior to shutting off 2 Purificaction Button P Press air purification function is activated the compressor does not work after entering the mode the fan work timing temperature scale and set the h...

Страница 4: ...nd humidity On the second line Job T working time and Humidity Setpoint are displayed on an alternating basis I n l e t 3 2 7 6 The contents of the second line alternateevery 10 sec 5 DEHUMIDIFIERS or...

Страница 5: ...e t t i n g 3 5 1 The Humidity Setting Humid a Press the Menu M button The screen shows b Press the M button until Humid is flashing Press OK to select this option The screen shows 8 Operation and Di...

Страница 6: ...then turn off 3 Cycling Timer T I O Selection The third selection T I O lets you set up the machine to cycle on and off during a specific time frame For example you could set the unit to run 8 hours a...

Страница 7: ...socket safely and reliably 2 through the Vias on Base and connect it to the water pipe which been fixed on water collector Put External pipe DEHUMIDIFIERS Maintenance and Repair 1 2 a out of the filte...

Страница 8: ...e from air inlet or air outlet No Airflow Unit is not level Place unit on flat surface in vertical orientation Place unit on flat surface in vertical orientation Loud Unusual Noise 1 3 Trouble code E1...

Страница 9: ...labor including but not limited to labor to remove and or reinstall any defective part refrigerant or piping Customer may elect to have unit fixed locally in which case required replacement parts will...

Отзывы: