The machine through a vapor compression refrigeration  principle  , which can efficiently 

remove airborne moisture . Especially for the home , office and other space dehumidification 

range  to  prevent  items  from  moisture  ,  mildew  ,  dry  clothes  can  protect  senior  musical 

instruments,  high-end furniture and other unaffected humid environment , to create a good 

living environment .

INTRODUCTION

Features/Specifications

Low Sound Levels <50dBA

Super Cop,2.8L/Kwh

The temperature control defrosting , more thorough, and more quick

Large Water trank

Humity can be fixed within 1%

Human handspike design

Water Full protection

R410A Refrigerant

Self-Checking Function

Automatic humidistat control,Display Tube TEM

Timing

Memory starting

Big Shock-proof  Wheels

Purification

Note: 

This dehumidification  capacity is at room temperature 30 ℃, relative  humidity  of 

80% income test conditions

Customer Service:

For additional questions concerning the operation of your dehumidifier, 

Identification:

Model Number     Ironmen 50L

Serial Number__________________________

Date of Purchase__________________________

For future reference, write down the model, serial number, and date of purchase so you 

can identify your unit when seeking assistance.  NOTE:  data label on back of unit includes 

serial number.

DEHUMIDIFIERS

Contact your installing contractor 

Email: [email protected]  

please:

WARNING

1

Unplug when cleaning or storing this dehumidifier .

2.

 Do not immerse the machine in water or near water .

3.

 Do not place the machine near a heating device or flammable dangerous place.

4.

 Do not put your fingers or other objects into the outlet or plug the outlet .

5.

 Do not sit on this machine table .

6.

 Follow the requirements of the tank to drain .

7. 

Before moving the machine , use the manual drain key discharged within 

consuming water.

8. 

Do not use this machine in a sealed environment to avoid fire.

9. 

Make sure the condensate drain down the installation so that you can continue

 

to 

be excluded .

10.

 If the power cord is damaged, you buy the same specifications of the power line 

to be replaced.

.

 

When using this machine , please note the following safety warnings :

DEHUMIDIFIERS

-2

-

Installation:

WARNING! 

120 Volts AC may cause serious injury from electric shock.

1. Disconnect electrical power before servicing       2. Only plug unit into grounded electrical outlet

3. Do not use extension cord                             4. Do not use plug adapter

Power Supply:

                      115V, 60 Hz AC Only 1 Phase

Outlet Requirement:

           3-Prong, GFI

Circuit Protector:                

15 Amp Time Delay Fuse or Circuit Breaker

Содержание Ironmen 50L

Страница 1: ...Ironmen 50L E mail sales alorair com Add North Carolina USA Installation and Operations Manual ALORAIR ALORAIR Registrate by scanning...

Страница 2: ...f purchase so you can identify your unit when seeking assistance NOTE data label on back of unit includes serial number DEHUMIDIFIERS Contact your installing contractor Email sales alorair com please...

Страница 3: ...ute prior to shutting off 2 Purificaction Button P Press air purification function is activated the compressor does not work after entering the mode the fan work timing temperature scale and set the h...

Страница 4: ...nd humidity On the second line Job T working time and Humidity Setpoint are displayed on an alternating basis I n l e t 3 2 7 6 The contents of the second line alternateevery 10 sec 5 DEHUMIDIFIERS or...

Страница 5: ...e t t i n g 3 5 1 The Humidity Setting Humid a Press the Menu M button The screen shows b Press the M button until Humid is flashing Press OK to select this option The screen shows 8 Operation and Di...

Страница 6: ...then turn off 3 Cycling Timer T I O Selection The third selection T I O lets you set up the machine to cycle on and off during a specific time frame For example you could set the unit to run 8 hours a...

Страница 7: ...socket safely and reliably 2 through the Vias on Base and connect it to the water pipe which been fixed on water collector Put External pipe DEHUMIDIFIERS Maintenance and Repair 1 2 a out of the filte...

Страница 8: ...e from air inlet or air outlet No Airflow Unit is not level Place unit on flat surface in vertical orientation Place unit on flat surface in vertical orientation Loud Unusual Noise 1 3 Trouble code E1...

Страница 9: ...labor including but not limited to labor to remove and or reinstall any defective part refrigerant or piping Customer may elect to have unit fixed locally in which case required replacement parts will...

Отзывы: