7
ALMECO nv
Air and water technologies
Royennestraat 51, B-7700 Moeskroen
[email protected] - www.almeco.eu
JETBLACK SAFET Y PERSONNEL CLEANING STATION
6. SPARES LIST
If you require any spare parts for your JetBlack unit, either Wall Mounted or Portable versions, please refer to the following
Almeco part numbers:
Almeco Part Number
Part Description
B3.003.049
Moulded Cleaning Station with full OSHA nozzle assembly (includes dip-moulded nozzle)
B3.003.052
Dip-moulded OSHA nozzle fitting
B3.002.787
Flexible hose assembly for wall-mounted JetBlack unit – 1.5m in length
B3.003.054
Replacement paper filter element
B3.003.050
Touch activated touch switch for wall-mounted Cleaning Station 230V
B3.003.324
Touch activated touch switch for wall-mounted Cleaning Station 110V
B3.000.976
230V replacement motor
B3.003.325
110V replacement motor
B3.003.057
230V replacement brushes
B3.003.438
110V replacement brushes
7. TROUBLE SHOOTING
Malfunction
Possible Cause
Remedy
Low Airflow
Dirty or contaminated blower filter
This item MUST be changed regularly.
Almeco recommend the filter is changed every 3
months subject to operating conditions
Damaged hose
Replace damaged hose
Blockage in air ducting
Check all ducting and air delivery devices for
blockages /damage and replace as necessary
Irregular / Excessive Noise Leak in air delivery ducting
Check and replace damaged hose and clips
Noisy motor
Replace motor
No power available
Check the supply and switch, and replace as necessary
Anti-static not working
(portable)
Anti-static control box is off
Switch anti-static control box to on position
Fuse has blown
Replace fuse (0.75A anti-surge)
Unit fails to operate
Burnt out motor brushes
Replace brushes
No power to unit
Check power supply is live including all fuses/MCBs
Motor has failed
Replace motor