background image

6

ALMECO nv 

Air and water technologies

Royennestraat 51, B-7700 Moeskroen

[email protected] - www.almeco.eu

JETBLACK SAFET Y PERSONNEL CLEANING STATION

5. ONDERHOUD & SERVICES

The following points must be observed when performing any maintenance or 

service operations to the Cleaning Station: 

• 

Filters – we recommend that the filter is inspected at least once a month, 

and replaced after a maximum of 3 months

• 

The power supply must be disconnected and secured against restoration

• 

Observe personal safety regulations

CHANGING FILTERS

• 

Wall mounted filters:

 first remove the M5 screw / filter guard as shown on 

the image below, and pull the filter out of its locating hole, then re-insert a 

new filter and refit filter guard.

• 

Portable unit filters: 

First remove the 4 fixing screws / filter guard as shown 

on the image below, and pull out the plug filter, then re-insert new plug 

filter, and secure guard and screw.

MOTOR BRUSH REPLACEMENT

• 

Ensure that the power supply is turned off, and that the Cleaning Station is 

electrically isolated and locked off

• 

Remove all screws retaining the main Cleaning Station outer cover, and lift 

cover off (see right)

• 

Unscrew 2 screws from the plastic motor cover, and remove cover (see 

below)

• 

There are two plastic brush holders to be removed. Unscrew 2 self-tap 
screws per brush set

• 

Remove the female receptacle motor lead from the old brushes

• 

Refit new brushes. Assembly is the opposite of removal

Содержание Jetblack Safety

Страница 1: ...www almeco eu DRYING BLOW OFF SOLUTIONS JETBLACK SAFETY PERSONNEL CLEANING STATION Wall mounted portable versions Installation operation and maintenance instructions...

Страница 2: ...meco eu Manual content 1 General safety information 3 2 Cleaning station safety information 3 3 Your new unit 4 4 Installation 5 5 Maintenance service 6 6 Spare parts 7 7 Trouble shooting 7 8 Waranty...

Страница 3: ...shutoff device for safety purposes Prolonged use may cause the unit to shut off In this case switch the unit off and wait for a few minutes before re using Please note the air from the Cleaning Statio...

Страница 4: ...lease immediately contact the Distributor that you purchased it from NOZZLE ASSEMBLY DETACHMENT Rotate the black coloured quick release fitting 90 degrees until it clicks Push the upper ring towards t...

Страница 5: ...on using the four holes in the baseplate Ensure the four spacers supplied are fitted under the baseplate when fitting to the wall If the Cleaning Station is already fitted to the wall remove and fit s...

Страница 6: ...mage below and pull the filter out of its locating hole then re insert a new filter and refit filter guard Portable unit filters First remove the 4 fixing screws filter guard as shown on the image bel...

Страница 7: ...motor B3 003 325 110V replacement motor B3 003 057 230V replacement brushes B3 003 438 110V replacement brushes 7 TROUBLE SHOOTING Malfunction Possible Cause Remedy Low Airflow Dirty or contaminated b...

Страница 8: ...f this document If the defect was due to accident or misuse operation in an application not approved by Almeco or unauthorised modification or repair Consumable parts and their routine replacement suc...

Отзывы: