TERMINAL BLOCKS
10 POLE TERMINAL BLOCK (M1
):
01-02 = Light of Courtesy Exit of 24Vdc. 3W max.
02-03 = N.C. contact enter photocell Low
02-04 = N.C. contact enter photocell High
05-06 = N.C. block enter (electronic block)
07-09 = N.O. button enter of OPEN
08-09 = N.O. button enter of CLOSE
09-10 = Exit 24Vdc. 500mA max. (10 = + 24V)
3 POLE TERMINAL BLOCK (M2):
11-12 = N.C. End-run enter of OPEN (12 = common) - STOP OPEN
12-13 = N.C. End-run enter of CLOSE (12 = common) - STOP CLOSE
2 POLE TERMINAL BLOCK (M3):
14-15 = Blinker exit of 24Vac.
max. 25W
2 POLE TERMINAL BLOCK (M4):
19-20 = Exit Blinker 230Vac.
max. 30W
4 POLE TERMINAL BLOCK (M5):
R-S-T = Input 400Vac or R-S = Input 230Vac
4 POLE TERMINAL BLOCK (M6):
U-V-W = Output 400Vac (or 230Vac - V=Commun)
4 POLE TERMINAL BLOCK (M7):
21-22 = Input Arial RX Radio (22 = Hold)
23-24 = Exit from RX Radio Channel 2
6 POLE TERM. BLOCK (M8):
25-26 = Input N.C. Contact MUSHROOM
27-28 =
N.O. button enter of OPEN
28-29 =
N.O. button enter of CLOSE
28-30 =
N.O. button enter of PEDESTRIAN
2 POLE TERMINAL BLOCK (M9
):
31-32 = N.C. = semi-automatic - N.O.= automatic
5 POLE TERMINAL BLOCK (M10):
33-34 =
LUC = Contact enter N.O. to disable the low photocell
and the DW in the last centimetres of closing (when N.C. disable).
34-35 = AP/CH = N.O. Buttom enter of OPEN/CLOSE
Dynamic
With SW1 - Dip 4 at ON : Dynamic = at every impulse : Open – Block – Close – Open etc.)
With SW1 - Dip 4 at OFF: Dynamic = Open - Close (on end-run)
36-37 = TX24V = Supply Exit 24Vdc for photocells (for autotest)
Only photocells transmitter
+24Vdc. high
0V (-) low
3 POLE TERMINAL BLOCK (M11):
If shunt on 16-17 = Input at 230V (Monophase or Treephase)
If shunt on 17-18 = Input at 400Vac. (set of factor)
= Input EARTH
ExitCommand
For Front Panel
= Output EARTH