Regulatin Times (Dip Swich SW2)
WORKING TIME
:
Dip 1 OFF
min.
27
sec.
MAX
50
sec.
Dip 2 OFF
Dip 1 OFF
min.
80
sec.
MAX
150
sec.
Dip 2 ON
Dip 1 ON
min.
04
sec.
MAX
30
sec.
(set of factor)
Dip 2 OFF
Dip 1 ON
min.
04
sec.
MAX
150
sec.
Dip 2 ON
PAUSE TIME
:
min
01
sec.
MAX
70
sec.
(set of factor)
With R11 shunt the max time is 200 sec.
PEDESTRIAN TIME
:
min.
02
sec.
MAX
13
sec.
REVERSAL TIME
:
Dip 3 OFF
reversal time =
0,5
sec.
Dip 4 OFF
Dip 3 OFF
reversal time =
1
sec. (set of factor)
Dip 4 ON
Dip 3 ON
reversal time =
2
sec.
Dip 4 OFF
Dip 3 ON
reversal time =
4
sec.
Dip 4 ON
SHUNTS SET
W3 - W4 – W5 – W6 – W7 = For predisposition type of Rx Radio (on costumer request)
W8 Shunted: DW control not connected
Free: DW control connected (insert DW24 in J3 position)
W1 Shunted 1-2 (central – left) CH2 of receiver
FOR
PEDESTRIAN ORDER
Shunted 2-3 (central – right) CH2 of receiver
FOR
CLOSE ORDER
W2 Shunted 4-5 (central – left) CH1 of receiver
FOR
DYNAMIC ORDER
Shunted 5-6 (central – right) CH1 of receiver
FOR
OPEN ORDER