DIP FUNCTIONS

 (Dip Switch SW1)

 

 

DIP 1 

ON :

   

LEAF DOOR FUNCTION ACTIVATED 

( photocell stops movement in opening)

 

 

 

 

 

 

 

 

OFF:   

LEAF DOOR (P. L.) DISACTIVATED 

 
 
DIP 2 

ON :

   

ANTI-DRAGGING FUNCTION ACTIVATED 

(with low and/or hight photocell  

 

 

 

 

 obscured, the control does not grasp the opening order) 

 
 
 

 

OFF :  

ANTI-DRAGGING DISACTIVATED 

 
 
DIP 3 

ON :

   

PRESSED BUTTON FUNCTION 

(look at the instructions next page) 

 
 

 

OFF :  

PRESSED BUTTON DISACTIVATED : 

Automatic or Semiautomatic cycle

 

 
 
DIP 4 

ON :

   

DYNAMIC FUNCTION ON BUTTOM : OPEN - BLOCK  -  CLOSE 

 
 

 

OFF :  

DYNAMIC FUNCTION DISACTIVATED  (

Normal Cycle: Open - Close)

 

 
 
DIP 5 

ON :

   

THE BLINKER BLINKS DURING ALL THE CYCLE 

 

 

 

 

 (il pulsante di blocco – 5 e 6 di M1 - lo spegne) 

 
 

 

OFF :  

THE BLINKER FIRST BLINK 4 SEC BEFORE CLOSING  

 

 

 

 

 (the button of block – 5 and 6 of M1 - switches it off) 

 
 
DIP 6 

:      ON :

   

AUTO-TEST FUNCTION  DW24B ACTIVATED 

 
              

OFF :  

AUTO-TEST DW24B  DISACTIVATED  

 
 
DIP 7

ON :

   

AUTO-TEST FUNCTION LOW PHOTOCELL ACTIVATED 

 
 

 

OFF :  

AUTO-TEST LOW PHOTOCELL DISACTIVATED 

 
 
DIP 8 

ON :

   

AUTO-TEST FUNCTION HIGH PHOTOCELL ACTIVATED 

 
 

 

OFF :  

AUTO-TEST HIGH PHOTOCELL DISACTIVATED 

 
 
 

 

WARNING OF FAILURE AUTOTEST 

:  

 
- If the low photocell does not work, the blinker advises with a blink of 2 seconds and the control 
   does not move. 
 
- If the hight photocell does not work, the blinker advises with 2 blink of 2 seconds and the control 
   does not move. 
 
-  If the DW 24B does not work, the blinker advises with 3 blink of 2 seconds and the control 
   does not move. 

Содержание Micro6R

Страница 1: ...AT THE FOLLOWING PRODUCT Product Name Central for Rapid Rolling Door Model Micro6R CONFORMS TO THE FOLLOWING EMC SPECIFICATIONS BASED ON SAMPLE TESTING EN 55011 EN 60335 1 EN 55014 1 EN 60204 1 EN 550...

Страница 2: ...K M7 21 22 Input Arial RX Radio 22 Hold 23 24 Exit from RX Radio Channel 2 6 POLE TERM BLOCK M8 25 26 Input N C Contact MUSHROOM 27 28 N O button enter of OPEN 28 29 N O button enter of CLOSE 28 30 N...

Страница 3: ...THE CYCLE il pulsante di blocco 5 e 6 di M1 lo spegne OFF THE BLINKER FIRST BLINK 4 SEC BEFORE CLOSING the button of block 5 and 6 of M1 switches it off DIP 6 ON AUTO TEST FUNCTION DW24B ACTIVATED OF...

Страница 4: ...e opening OPEN END RUN STOP THE OPENING CLOSE END RUN STOP THE CLOSING BLOCK BLOCK THE MOVEMENT With DIP8 on ON A HIGH PHOTOCELL PHOTOCELL BLOCKS IN OPENING With DIP7 on ON B LOW PHOTOCELL PHOTOCELL B...

Страница 5: ...versal time 0 5 sec Dip 4 OFF Dip 3 OFF reversal time 1 sec set of factor Dip 4 ON Dip 3 ON reversal time 2 sec Dip 4 OFF Dip 3 ON reversal time 4 sec Dip 4 ON SHUNTS SET W3 W4 W5 W6 W7 For predisposi...

Страница 6: ...working time combination P1 The control works with normally closed End run N C With the gate opened the pause timer It can be bypassed pressing the button of close after the deter minated time P2 will...

Страница 7: ...hen the motor opens The motor does not open the door com pletely Control close at once Control reverse the movement bru squely Photocell stops on Open Control does not open Control does not open Times...

Страница 8: ...l have a load of 9 Amp And they must be relating to their load periodically checked It is advisable to overhaul the relay contacts every 4 years but always according to the following condi tions Micro...

Отзывы: