background image

WIRING DIAGRAM  

19 

C

D

O

M

C

B

 2

005

EDGE

RADIO

c.

p. ALLSTAR

 C

O

RP

.

P4

24V

S1

R58

R56

R55

R54

R45

R46

R53

PC

B

 11269

R

E

V

 B

 T

S

L

K

K2

K4

K3

K5

K6

CO

M

OL

S

CL

S

CO

M

HIGH VOLTAGE

OPE

N

MO4

MO3

MO2

MO1

ILK

24V

COM

VCC

FRA

COM

24V

RM1

RM2

RM3

VCC

COM

P7

R8

R24

C12

TB1

STATUS

LD4

OFF

S4
S3
S2
S1

C25

R94

R87

R38

R22

R10

P5

PB1

PB2

PB3

R49

C6

R93

R90

U5

R62

R61

R60

R5

R25

R9

R23

R51

R19

R17

R13

R20

R18

R14

STOP

CLOSE

OPEN

R7

R6

R16

R15

R11

R12

POWER

C24

R85

U1

C2

RO

1

D8

U4

C1

1

R3

0

R2

6

R2

9

C3

C1

C

8

R47

R84

R95

SW1

R83

R82

R33

R34

R2

R3

R4

C21

R21

D2

R65

C10

D3

C9

TR4

TR2

R52

C14

TR1

R48

C13

TR3

R89

Q1

C7

D1

D12

R28

R27

C16

LD3

LD2

P2

P3

R1

C30

P1

R31

P6

R57

GROUND

GREY

NO

COM

COM

NO

CLOSE LIMIT

OPEN LIMIT

GREY

ORANGE
ORANGE

24 VAC

TRANSFORMER

LINE

YELLOW
YELLOW

INTERLOCK

CO

M

CLO

S

E

STOP

NO R

E

V

NC

 R

E

V

PHOT

O

CO

M

SIN

G

LE

ILOC

K

24 V

A

C

COM

SAFE FINISH PHOTOBEAM

3-WIRE PHOTOBEAM

RED

BLUE

WHITE

N

L1

YELLOW

BLACK

WHITE

*

BROWN

BR

AKE

T:   ON   OFF ON   OFF

TS: OFF OFF ON   OFF

E2: ON   ON   OFF OFF

D1: OFF ON   OFF OFF

B2: ON   OFF OFF OFF

C2: OFF OFF OFF OFF

SWITCH SETTING

OPERATING MODES

*

REMOVE FACTORY JUMPER
IF USING NC REV INPUT

Содержание MH5011S

Страница 1: ...S JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THIS MANUAL Serial Date Installed Your Dealer 100771 As of date of manufacture meets all ANSI...

Страница 2: ...fication Pictorial 4 Important Installation Warnings Things To Do Before During Installation 5 Table 1 Component Identification Listing 5 Installation Instructions 6 12 Figure 2 Operator Footprint 6 F...

Страница 3: ...lly Closed reversing devices such as foam or pneumatic reversing door edge components or a three wire photo beam are provided Constant Contact To Close Standard operating mode C2 programmable to Momen...

Страница 4: ...carton inspect the nameplate on the cover of the operator control box to verify that it is the correct model for the intended application and that the voltage and phase are in accordance with electri...

Страница 5: ...Head 1 2 005031 3 Button Station 1 3 009062 30 Tooth Sprocket 1 Bore 1 4 Key 1 4 009061 20 Tooth Sprocket 1 Bore 1 4 key 1 5 105193 Release Hand Chain Wall Bracket 1 AR As Required ITEM PART DESCRIPT...

Страница 6: ...OF THE OPERATOR If the construction permits the operator should be mounted with 3 8 inch diameter bolts through the wall If it is not feasible to go through the wall then use lag bolts to fasten the o...

Страница 7: ...of pliers If the chain is too long standard length for 16 foot high doors and below is 26 feet total length of chain shorten it to the desired length using the method described above and discard the...

Страница 8: ...100769 100771 FIGURE 5 OPERATOR DIMENSIONS MODEL MJ5011S 8 FIGURE 5A OPERATOR DIMENSIONS MODEL MH5011S...

Страница 9: ...everse Cutout Limit nut E and the Reverse Cutout Limit switch A The actual Close Limit position is a timed function whereas the door continues to run for a certain period of time after the Reverse Cut...

Страница 10: ...ide the cover of the control box details all of the field wiring terminal connections for the operator Always connect the wires to the push button controls and auxiliary devices exactly as shown Warni...

Страница 11: ...ISH PHOTOBEAM 3 WIRE PHOTOBEAM MOTOR CONTROL BOARD Door Edge and Photoelectric Wiring Figure 9 See text on page 10 for operation when Safe Finish or Access Alliance Safe Finish II photo beams are conn...

Страница 12: ...is clear PCB 112695 REV B TSLK OPEN C25 PB1 PB2 PB3 U5 STOP CLOSE OPEN C1 R84 R2 R3 D12 COM CLOSE STOP NO REV NC REV PHOTO RADIO 24V R56 R55 R54 PCB 112695 REV B TSLK OPEN RM1 RM2 RM3 VCC COM P7 C25 R...

Страница 13: ...cles per hour Permanently install this label adjacent to the door near the push button station at the eye height of the average adult approximately six feet above the above the floor DO NOT over adjus...

Страница 14: ...IPPING BECAUSE OF LOOSE OR MISSING HARDWARE BINDING IN THE TRACK RUBBING AGAINST THE DOOR STOPS OR DEFECTIVE OR MISADJUSTED SPRINGS ANY SERVICE REQUIRED TO THE DOOR DOOR SPRINGS OR DOOR OPERATOR MUST...

Страница 15: ...f closing door Reverse Momentary activation will reverse a closing door reverse to full open ignores mid stop unless stopped by stop pushbutton input Mid Stop Activation stops an opening door momentar...

Страница 16: ...ion to open open override of closing door closes door from mid stop or open limit Reverse Momentary activation will reverse a closing door reverse to full open ignores mid stop unless stopped by stop...

Страница 17: ...if desired by pressing the Open button A single button input when the door is at the mid stop position will cause the door to begin moving in the close direction The factory default is not set the min...

Страница 18: ...R OBJECT If the operator is equipped with other means of control such as additional 3 button stations or radio controls each of these should be tested separately for proper operation To test the manua...

Страница 19: ...O1 D8 U4 C11 R30 R26 R29 C3 C1 C8 R47 R84 R95 SW1 R83 R82 R33 R34 R2 R3 R4 C21 R21 D2 R65 C10 D3 C9 TR4 TR2 R52 C14 TR1 R48 C13 TR3 R89 Q1 C7 D1 D12 R28 R27 C16 LD3 LD2 P2 P3 R1 C30 P1 R31 P6 R57 GROU...

Страница 20: ...caused by improper installation or care vandalism or lightning fire or excessive heat flood or other acts of God including but not limited to misuse abuse or alterations failure to provide reasonable...

Отзывы: