background image

The purpose

 

of this booklet is to provide assembly, 

installation and operation information concerning Allstar 

Model MJ5011S & MH5011S (MS Series) Commercial 

Vehicular Garage Door Operators and related Accessory 

Products. 

NOTICE 

IT IS IMPORTANT THAT THIS INSTRUCTION 

MANUAL BE READ AND UNDERSTOOD 

COMPLETELY BEFORE INSTALLATION OR 

OPERATION IS ATTEMPTED.  IT IS INTENDED 

THAT THE INSTALLATION OF THIS UNIT WILL BE 

DONE ONLY BY PERSONS TRAINED AND 

QUALIFIED IN THE INSTALLATION, ADJUSTMENT 

AND SERVICE OF COMMERCIAL OVERHEAD 

DOORS AND DOOR OPERATORS AND BY 

QUALIFIED ELECTRICIANS. 

NOTICE 

THE IMPORTANT SAFEGUARDS AND 

INSTRUCTIONS IN THIS MANUAL CANNOT 

COVER ALL POSSIBLE CONDITIONS AND 

SITUATIONS WHICH MAY OCCUR DURING ITS 

USE.  IT MUST BE UNDERSTOOD THAT COMMON 

SENSE AND CAUTION MUST BE EXERCISED BY 

THE PERSON(S) INSTAL- LING, MAINTAINING 

AND OPERATING THE EQUIPMENT DESCRIBED 

HEREIN.  DO NOT USE THIS EQUIPMENT FOR 

ANY OTHER THAN ITS INTENDED 

PURPOSE - OPERATING OVERHEAD 

COMMERCIAL VEHICULAR GARAGE DOORS.

 

 

STANDARD FEATURES 

Solid State Controls: 

 The Allstar MJ5011S & MH5011S 

operators employ solid state technology with advanced 

standard features to provide for a complete commercial 

door operating system. 

Limit Switches:

 

 Driven limit switches, easily adjusted 

over a wide range.  The motor may be removed without 

affecting the limit switch adjustments. 

Manual Release:

  Permits manual operation of the door 

in the event of a power failure.  The Model MH511S is 

equipped with a chain hoist to aid in manual operation.  

Control Circuit:

 

 Connection terminals for a standard 

three button Open, Close and Stop control station at 5 Volts 

DC.  The motor control board features a built-in 3 button 

station for test purposes.

 

Connections For Auxiliary Entrapment Protection 

Devices:  

For the ultimate in protection, terminals are 

provided to connect an Allstar Safe-Finish™ or Access 

Alliance Safe-Finish II™ monitored photo-beam system. 

Additional connection terminals for a Normally Open and 

Normally Closed reversing devices such as foam or 

pneumatic reversing door edge components or a three wire 

photo-beam are provided. 

Constant Contact To Close:

  Standard operating mode 

(C2), programmable to Momentary Contact To Close (B2) 

and four additional operational modes.

MS SERIES DOOR OPERATOR APPLICATIONS:

 

Jackshaft operators are intended for commercial and 
industrial use to raise or lower sectional overhead doors 
by chain coupling or direct coupling to the door shaft. 
Jackshaft operators are suitable where all or part of the 
door remains in a vertical position when fully open such as 
doors with at least 18 inches of lift clearance or full vertical 
lift doors. MS Series Jackshaft operators may also be 
used with certain roll up service doors and grills when 
appropriately sprocketed (consult factory).   
 
A jackhaft operator 

DOES NOT LOCK THE DOOR IN ITS 

CLOSED POSITION.

 However, because the cross-header 

shaft is prevented by the operator from turning, the torsion 
springs provide no assistance in lifting the door should an 
attempt be made to raise it manually.                                               
 

The MS Series jackshaft operators are used in the 
following applications: 

Intermittent Duty, Limited Cycle Commercial 
installations only 

Rate of operation shall not exceed 10 cycles of 
opening and closing per hour, maximum 60 cycles 
per day. 

Indoor Use Only 

Up to 14 foot high doors with a maximum area of 

196 square feet, maximum area slightly higher for 

lighter doors - consult factory 

Use with foam/pneumatic reversing door edge or 

photoelectric device - REQUIRED where the 3-

button station is out of sight of the door, or 

any

 

other automatic, remote or manual control is used 

to activate the door 

OPTIONAL FEATURES:

 

Digital Radio Controls:

 

 Open, Close and Stop 

operation.  Radio units are available to control up to 27 

doors from one transmitter. 

Timer to Close Operation:

   Two of the 

programmable operation modes (T & TS), closing delay is 

adjustable from 5 seconds (factory set at 30 seconds) to 

5 minutes in five second intervals. 

Delay on Reverse

Factory set to 0.6 seconds, 

adjustable to 2 seconds. 

Keyless Entry System:

 

 Connection terminals 

provided for hard wired or wireless keyless entry systems. 

 PRODUCT FEATURES 

Содержание MH5011S

Страница 1: ...S JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THIS MANUAL Serial Date Installed Your Dealer 100771 As of date of manufacture meets all ANSI...

Страница 2: ...fication Pictorial 4 Important Installation Warnings Things To Do Before During Installation 5 Table 1 Component Identification Listing 5 Installation Instructions 6 12 Figure 2 Operator Footprint 6 F...

Страница 3: ...lly Closed reversing devices such as foam or pneumatic reversing door edge components or a three wire photo beam are provided Constant Contact To Close Standard operating mode C2 programmable to Momen...

Страница 4: ...carton inspect the nameplate on the cover of the operator control box to verify that it is the correct model for the intended application and that the voltage and phase are in accordance with electri...

Страница 5: ...Head 1 2 005031 3 Button Station 1 3 009062 30 Tooth Sprocket 1 Bore 1 4 Key 1 4 009061 20 Tooth Sprocket 1 Bore 1 4 key 1 5 105193 Release Hand Chain Wall Bracket 1 AR As Required ITEM PART DESCRIPT...

Страница 6: ...OF THE OPERATOR If the construction permits the operator should be mounted with 3 8 inch diameter bolts through the wall If it is not feasible to go through the wall then use lag bolts to fasten the o...

Страница 7: ...of pliers If the chain is too long standard length for 16 foot high doors and below is 26 feet total length of chain shorten it to the desired length using the method described above and discard the...

Страница 8: ...100769 100771 FIGURE 5 OPERATOR DIMENSIONS MODEL MJ5011S 8 FIGURE 5A OPERATOR DIMENSIONS MODEL MH5011S...

Страница 9: ...everse Cutout Limit nut E and the Reverse Cutout Limit switch A The actual Close Limit position is a timed function whereas the door continues to run for a certain period of time after the Reverse Cut...

Страница 10: ...ide the cover of the control box details all of the field wiring terminal connections for the operator Always connect the wires to the push button controls and auxiliary devices exactly as shown Warni...

Страница 11: ...ISH PHOTOBEAM 3 WIRE PHOTOBEAM MOTOR CONTROL BOARD Door Edge and Photoelectric Wiring Figure 9 See text on page 10 for operation when Safe Finish or Access Alliance Safe Finish II photo beams are conn...

Страница 12: ...is clear PCB 112695 REV B TSLK OPEN C25 PB1 PB2 PB3 U5 STOP CLOSE OPEN C1 R84 R2 R3 D12 COM CLOSE STOP NO REV NC REV PHOTO RADIO 24V R56 R55 R54 PCB 112695 REV B TSLK OPEN RM1 RM2 RM3 VCC COM P7 C25 R...

Страница 13: ...cles per hour Permanently install this label adjacent to the door near the push button station at the eye height of the average adult approximately six feet above the above the floor DO NOT over adjus...

Страница 14: ...IPPING BECAUSE OF LOOSE OR MISSING HARDWARE BINDING IN THE TRACK RUBBING AGAINST THE DOOR STOPS OR DEFECTIVE OR MISADJUSTED SPRINGS ANY SERVICE REQUIRED TO THE DOOR DOOR SPRINGS OR DOOR OPERATOR MUST...

Страница 15: ...f closing door Reverse Momentary activation will reverse a closing door reverse to full open ignores mid stop unless stopped by stop pushbutton input Mid Stop Activation stops an opening door momentar...

Страница 16: ...ion to open open override of closing door closes door from mid stop or open limit Reverse Momentary activation will reverse a closing door reverse to full open ignores mid stop unless stopped by stop...

Страница 17: ...if desired by pressing the Open button A single button input when the door is at the mid stop position will cause the door to begin moving in the close direction The factory default is not set the min...

Страница 18: ...R OBJECT If the operator is equipped with other means of control such as additional 3 button stations or radio controls each of these should be tested separately for proper operation To test the manua...

Страница 19: ...O1 D8 U4 C11 R30 R26 R29 C3 C1 C8 R47 R84 R95 SW1 R83 R82 R33 R34 R2 R3 R4 C21 R21 D2 R65 C10 D3 C9 TR4 TR2 R52 C14 TR1 R48 C13 TR3 R89 Q1 C7 D1 D12 R28 R27 C16 LD3 LD2 P2 P3 R1 C30 P1 R31 P6 R57 GROU...

Страница 20: ...caused by improper installation or care vandalism or lightning fire or excessive heat flood or other acts of God including but not limited to misuse abuse or alterations failure to provide reasonable...