background image

6 / 16

6-1624982 - rev.1 - 20/05/2021

ENG

4. PRODUCT VIEW AND TECHNICAL CHARACTERISTICS

TABLE 2 - HYPER 400 technical characteristics

TECHNICAL CHARACTERISTICS

U.M.

HYPER 400

Recommended control board

BIOS2 24

BIOS2 120 / 

ECO

BIOS2 230 / 

ECO

Supply voltage and frequency

24 Vdc

120Vac 60Hz

230Vac 50Hz

Motor absorption

A

3

1

1

Motor power

W

70

120

230

Capacitor

μF

--

31,5

8

Motor speed

rpm

1700

1750

1450

Average opening time (90°)

sec.

17

17

20

Maximum gate size (Weight/Length)

100 kg / 3 m
133 kg / 2,5 m
200 kg / 1,5 m

150 kg / 3 m
183 kg / 2,5 m
250 kg / 1,5 m

200 kg / 3 m
233 kg / 2,5 m
300 kg / 1,5 m

Maximum thrust

N

1600

2000

2000

Service

%

70

50

50

Recommended daily cycles

100

100

100

Weight of the motor

kg

6

7

7

Operating temperature

°C

-20°C ... +55°C

Degree of protection

IP

44

Emergency release

lever release with key

Internal mechanical stoppers

optional

A. 

Motor body

B. 

Motor stem

C. 

Motor supply cable

D. 

Key to unlock

E. 

Release lever to unlock

F. 

Fixing point for rear bracket

G. 

Fixing point for front bracket

H. 

Screws for adjusting internal mechanical stoppers (op-
tional)

Description:

A

B

G

H

E

F

C

D

Содержание HYPER 400

Страница 1: ...HYPER Ambidextrous irreversible operator for swing door gates 6 1624982 ENGLISH rev 1 20 05 2021...

Страница 2: ...WARNINGS 3 2 DESCRIPTION 3 3 LIST OF PACKAGING ACCESSORIES AND OVERALL DIMENSIONS 4 4 PRODUCT VIEW AND TECHNICAL CHARACTERISTICS 6 5 PRELIMINARY CHECKS 8 6 INSTALLATION 11 7 DECLARATION OF CONFORMITY...

Страница 3: ...is provided with thermal protection that in case of prolonged use momentarily interrupts the movement The HYPER motor provides great flexibility of installation as you can install it with the motor b...

Страница 4: ...ppers 0 1 2 0 1 2 230Vac 50Hz 12008100 12008101 12008102 12008130 12008131 12008132 120Vac 60Hz 12008110 12008111 12008112 12008140 12008141 12008142 24Vdc 12008120 12008121 12008122 12008150 12008151...

Страница 5: ...790 HYPER 400 990 HYPER 600 810 HYPER 400 1010 HYPER 600 WITHOUT INTERNAL MECHANICAL STOPPERS WITH INTERNAL MECHANICAL STOPPERS 1 or 2 77 31 15 46 10 5 10 5 10 5 90 5 120 5 25 50 11 11 10 10 40 REAR...

Страница 6: ...ate size Weight Length 100 kg 3 m 133 kg 2 5 m 200 kg 1 5 m 150 kg 3 m 183 kg 2 5 m 250 kg 1 5 m 200 kg 3 m 233 kg 2 5 m 300 kg 1 5 m Maximum thrust N 1600 2000 2000 Service 70 50 50 Recommended daily...

Страница 7: ...s n 100 100 100 Weight of the motor kg 7 8 8 Operating temperature C 20 C 55 C Degree of protection IP 44 Emergency release lever release with key Internal mechanical stoppers optional TABLE 4 Stem st...

Страница 8: ...ause they are not sufficiently safe WARNING The doors shall be firmly attached to the hinges of the columns shall not flex during movement and shall move without friction Before installing the motor i...

Страница 9: ...tion of the various devices in a typical plant are listed in the table below and must be suitable for the type of installation for example we recommend a cable type H07RN F for outdoor installation TA...

Страница 10: ...wards or upwards depending on your needs WHAT NOT TO DO Do not install on sloping gates Do not unduly bend the motor cable Do not install the bracket in the gate in weak points that may break 5 4 MOTO...

Страница 11: ...73 104 968 102 160 987 108 992 110 983 105 978 102 973 100 968 98 180 991 100 986 98 981 96 976 94 971 93 966 91 200 989 92 984 90 982 90 981 90 976 88 964 85 TABLE 8 HYPER 600 Recommended installatio...

Страница 12: ...g dimensions For the anchor of the piston it is necessary to use additional supports not supplied together with the fixing brackets supplied These supports shall be appropriate to the dimension of the...

Страница 13: ...with the bracket already installed to the gate and temporarily fix the bracket to the gate 6 Verify that the motor is on level 7 Carry out some manual opening and closing movements in order to verify...

Страница 14: ...gnet and therefore the mechanical stopper as far as possible from the gate hinge 5 Repeat the operations described above also for the mechanical stopper of closing bringing the gate first in the posit...

Страница 15: ...ectrical connections and in case of wear of the cables replace them 4 Unlock the motor and move the gate manually by checking that the movement is fluid In case it is necessary to put a layer of lubri...

Страница 16: ...ction for disposal according to the methods provided by the regulations in force in your territory or return the product to the seller when buying a new equivalent product WARNING the regulations in f...

Отзывы: