background image

11 / 16 

6-1624982 - rev.1 - 20/05/2021

ENG

6. INSTALLATION

6.1 DETERMINE THE INSTALLATION MEASUREMENTS (OPENING INWARDS)

Before fixing the supplied brackets it is necessary to determine the installation dimensions A and B. 

Start by putting the gate in position of "CLOSED DOOR".

 

Choose the sizes of A and B according to your installation and in order to obtain the desired degree of opening "α". This grade shown 
in the table refers to 

the highest possible degree of openness

 with the corresponding dimensions.

To anchor the piston use the brackets provided.

TABLE 7 - HYPER 400 Recommended installation dimensions

A

155

160

165

170

175

180

B

W ( α )

150

980 (110°)

982 (110°)

984 (110°)

985 (110°)

973 (104°)

968 (102°)

160

987 (108°)

992 (110°)

983 (105°)

978 (102°)

973 (100°)

968 (98°)

180

991 (100°)

986 (98°)

981 (96°)

976 (94°)

971 (93°)

966 (91°)

200

989 (92°)

984 (90°)

982 (90°)

981 (90°)

976 (88°)

964 (85°)

TABLE 8 - HYPER 600 Recommended installation dimensions

A

220

230

240

250

260

270

B

W ( α )

220

1269 (110°)

1270 (110°)

1273 (110°)

1278 (110°)

1279 (110°)

1269 (107°)

240

1288 (110°)

1290 (110°)

1292 (110°)

1287 (107°)

1277 (104°)

1267 (101°)

260

1302 (108°)

1310 (110°)

1295 (104°)

1285 (101°)

1275 (99°)

1265 (97°)

280

1313 (105°)

1303 (101°)

1293 (98°)

1283 (96°)

1273 (94°)

1263 (92°)

A

B

W

TOP VIEW

INTERNAL SIDE OF 

THE PROPERTY

EXTERNAL SIDE 

OF THE PROPERTY

WARNING!

The values given in the following tables are indicative and have been calculated considering the ideal conditions with a 
gate of medium size, with a uniformly distributed filling and with both the internal mechanical stoppers installed. Keep 
in mind that values may vary slightly and must be checked in advance.

Содержание HYPER 400

Страница 1: ...HYPER Ambidextrous irreversible operator for swing door gates 6 1624982 ENGLISH rev 1 20 05 2021...

Страница 2: ...WARNINGS 3 2 DESCRIPTION 3 3 LIST OF PACKAGING ACCESSORIES AND OVERALL DIMENSIONS 4 4 PRODUCT VIEW AND TECHNICAL CHARACTERISTICS 6 5 PRELIMINARY CHECKS 8 6 INSTALLATION 11 7 DECLARATION OF CONFORMITY...

Страница 3: ...is provided with thermal protection that in case of prolonged use momentarily interrupts the movement The HYPER motor provides great flexibility of installation as you can install it with the motor b...

Страница 4: ...ppers 0 1 2 0 1 2 230Vac 50Hz 12008100 12008101 12008102 12008130 12008131 12008132 120Vac 60Hz 12008110 12008111 12008112 12008140 12008141 12008142 24Vdc 12008120 12008121 12008122 12008150 12008151...

Страница 5: ...790 HYPER 400 990 HYPER 600 810 HYPER 400 1010 HYPER 600 WITHOUT INTERNAL MECHANICAL STOPPERS WITH INTERNAL MECHANICAL STOPPERS 1 or 2 77 31 15 46 10 5 10 5 10 5 90 5 120 5 25 50 11 11 10 10 40 REAR...

Страница 6: ...ate size Weight Length 100 kg 3 m 133 kg 2 5 m 200 kg 1 5 m 150 kg 3 m 183 kg 2 5 m 250 kg 1 5 m 200 kg 3 m 233 kg 2 5 m 300 kg 1 5 m Maximum thrust N 1600 2000 2000 Service 70 50 50 Recommended daily...

Страница 7: ...s n 100 100 100 Weight of the motor kg 7 8 8 Operating temperature C 20 C 55 C Degree of protection IP 44 Emergency release lever release with key Internal mechanical stoppers optional TABLE 4 Stem st...

Страница 8: ...ause they are not sufficiently safe WARNING The doors shall be firmly attached to the hinges of the columns shall not flex during movement and shall move without friction Before installing the motor i...

Страница 9: ...tion of the various devices in a typical plant are listed in the table below and must be suitable for the type of installation for example we recommend a cable type H07RN F for outdoor installation TA...

Страница 10: ...wards or upwards depending on your needs WHAT NOT TO DO Do not install on sloping gates Do not unduly bend the motor cable Do not install the bracket in the gate in weak points that may break 5 4 MOTO...

Страница 11: ...73 104 968 102 160 987 108 992 110 983 105 978 102 973 100 968 98 180 991 100 986 98 981 96 976 94 971 93 966 91 200 989 92 984 90 982 90 981 90 976 88 964 85 TABLE 8 HYPER 600 Recommended installatio...

Страница 12: ...g dimensions For the anchor of the piston it is necessary to use additional supports not supplied together with the fixing brackets supplied These supports shall be appropriate to the dimension of the...

Страница 13: ...with the bracket already installed to the gate and temporarily fix the bracket to the gate 6 Verify that the motor is on level 7 Carry out some manual opening and closing movements in order to verify...

Страница 14: ...gnet and therefore the mechanical stopper as far as possible from the gate hinge 5 Repeat the operations described above also for the mechanical stopper of closing bringing the gate first in the posit...

Страница 15: ...ectrical connections and in case of wear of the cables replace them 4 Unlock the motor and move the gate manually by checking that the movement is fluid In case it is necessary to put a layer of lubri...

Страница 16: ...ction for disposal according to the methods provided by the regulations in force in your territory or return the product to the seller when buying a new equivalent product WARNING the regulations in f...

Отзывы: