4/20
6-1622400 rev. 8 19/01/2022
A
A
ENG
ITA
ENG
FRA
ESP
NLD
TUR
3.2 - MODELS AND TECHNICAL FEATURES
CODE
DESCRIPTION
12006685
BIOS1 24V control unit for a single motor
60550058
Transformer 230 / 23 Vac 150VA
12006730
Bluetooth module
12000760
R1 card
12000780
Battery charger 24CBA card
Transformer power supply
230Vac 50-60Hz
Fuse for transformer protection
T 1A
BIOS1 24V power supply
24Vac 50-60Hz
Maximum power of the motor output
240W
Flashing light output
24Vac 25W
Courtesy light / Open automation light output
24Vac 25W
24Vdc accessories power supply
24Vdc 5W
433MHz radio receiver
Rolling Code
Memorisable transmitters
1000
Operating temperature
-10°C +55°C
3.3 - LIST OF THE SUGGESTED CABLES
The suggested cables for the connection of the various devices in a standard system are listed in the following list.
The used cables must be suitable for the type of installation; for example, an H03VV-F type cable is recommended for indoor applications, while
H07RN-F is suitable for outdoor applications.
Connection
Cable
Maximum lenght
Line for the power supply
3 x 1,5 mm2
20 m *
Motor
2 x 1,5 mm2
20 m *
Flashing light
2 x 0,5 mm2
20 m
Courtesy light / Open automation light
2 x 0,5 mm2
20 m
Photocells - transmitter
2 x 0,5 mm2
20 m
Photocells - receiver
4 x 0,5 mm2
20 m
Safety edge
2 x 0,5 mm2
20 m
Key selector
4 x 0,5 mm2
20 m
* If the cable is more than 20 m long, it must be of larger gauge and a safety grounding system must be installed near the automation unit.
3.4 - PRELIMINARY CHECKS
- The gate shall move frictionless.
Note:
Gate features must be uniformed with the standards and laws in
force. The door/gate can be automated only if it is in a good condition and
if its conditions comply with the EN 12604 norm.
- The door/gate leaf should not have a pedestrian opening. In the opposite
case it is necessary to take the appropriate steps, in accordance with EN
12453 norm (for instance: by preventing the operation of the motor when
the pedestrian opening is opened, by installing a safety microswitch
connected with the control panel).
- Besides the electrical or mechanical limit switches available on the
operators, there must be, on both ends of the installation, a fixed
mechanical stopper which stops the gate in the unlikely event of bad
functioning of the limit swithces on the operators. For this reason the
fixed mechanical stopper must be of an adeguate size to withstand the
static and kinetic forces generated by the gate (A) (Fig.2).
The guide must be provided with two mechanical stops at its ends (A)
(Fig. 2).
- The gate columns shall have anti-derailment guides on their top (Fig. 3),
FIG. 2
Содержание BIOS1 24V
Страница 1: ...BIOS1 24V MADE IN ITALY CENTRALINA PER CANCELLI SCORREVOLI 24V...
Страница 21: ...BIOS1 24V CONTROL UNIT FOR SLIDING GATES AT 24V MADE IN ITALY...
Страница 41: ...BIOS1 24V CENTRAL DE COMMANDE POUR PORTAIL COULISSANT 24V MADE IN ITALY...
Страница 61: ...BIOS1 24V CUADRO DE MANDO PARA CANCELAS CORREDERAS 24V MADE IN ITALY...
Страница 81: ...BIOS1 24V BESTURINGSEENHEID VOOR SCHUIFPOORTEN 24V MADE IN ITALY...
Страница 101: ...BIOS1 24V 24V KAYAR KAPILAR N KUMANDA MERKEZ TALYAN MALI...