3. Operation
3-14
3.5
Operating Procedure
Make sure that all enclosure doors are closed before starting.
3.5.1 Operating Procedure
To start, please follow the procedure below.
Manual Start Procedure
<Procedure>
1. Set the circuit breaker [A] on the instrument panel to [OFF] position.
2. Set the selector switch [B] to [ON] position.
3. Push the manual mode button [C].
4. Push the start button [D] to run the engine.
(Preheating is started automatically in cold weather. After the glow lamp [E] is off, the engine starts.)
5. Once engine has started, let it warm up approximately 5 minutes at no-load condition.
A180895E
W013
Keep the output terminal cover shut and locked whenever the
machine is running. Note that a voltage of several hundred volts is
applied to the output terminal and control board. When opening
the output terminal cover is unavoidable, be careful not to touch
the output terminal. Electric shock or serious injury could result.
G B C F H D A
E
I