Camera interfaces
GUPPY Technical Manual
V4.0.1
106
Input
The inputs can be connected directly to +5 V. If a higher voltage is used, an
external resistor must be placed in series. Use at +12 V a 18 k
Ω
resistor and
at +24 V a 47 k
Ω
resistor.
Trigger
The signal can be inverted. The camera must be set to
external triggering
to
trigger image capture by the trigger signal.
Absolute maximum
ratings
Recommended
operating conditions
Description
Input voltage
-0.5 V ... +7.0 V
0 V ... + 5.5 V
5 V CMOS
Input rise and fall time
Schmitt trigger
implemented
Input clamping voltage 24 V
Input pulse width
(min.)
> 1µs
Digital input filter
Table 38: Input characteristics
Warning
a
Voltages higher than 24 V DC may damage the camera.
Figure 50: Input block diagram